Repair manual
ELECTRIC STEAM GENERATOR (BOILER) ASSEMBLY - 2
PROBE TYPE
18 KW, 27 KW, 36 KW, & 48 KW (2, 3, & 4 HEATER ELEMENTS)
REFERENCE
NUMBER
PART
NUMBER
DESCRIPTION REFERENCE
NUMBER
PART
NUMBER
DESCRIPTION
1
43894
Elect
ric Boiler Shell only. with legs. hand hole
08216
Heater,
12 KW. 440/480
volt,
1
phase
plate assembly, mounting studs tor 3' square
08217 Heater. 12 KW. 600 volt. 1 phase
flanged heater elements
10
07128
Heater Gasket
44149
Electric Boiler
Shell
(43894)
above, also include
1
1
16546
3
-
Block
-
Off Plate
ing sight gauge, two probes and extensions with 12 22131 15 psi Safety Valve
cow box.
22130 8 psi Safety Valve
2 40421 Hand Hole Plate Assembly including oar. nut. 13 19947 Pressure Switch
and gasket. 14 03509 Contactor 50 amp
2a 43748 Hand Hole Plate only
03506 Contactor. 75 amp
3 07106
Hand Hole Gasket. 4' x 6' oval
15 23198 Control Board, water level ana LWCO
&
40462 Probe 16 03524 Relay
5 101466 Probe Extension Set (set of two) 17 03525 Relay Socket
6 52305 Probe Cover Box 18 44168 Terminal Block. 2 pole
7 40445 Water Gauge Set with Glass 19 03202 Circuit Breaker, 1 amp
07108 Fibre Washer (2 required) 20 20478 interval Timer. 3 minute
23132 Gauge Glass Washer (2 required) 21 20535 Transformer. 150 VA
8 07302 Gauge Glass Only. 6' long 22 22102
Check valve, 3/4. •
9 08235 Heater. 9 KW. 208 volt. 3 phase 23 03276 1/4 " Ban Valve, water supply shut-off
08236 Heater. 9 KW. 220/240 volt. 3 phase 24
22223
Solenoid Valve, water feed
08237 Healer. 9 KW. 440/480 volt 3 phase 25 19870 Line Strainer. 1/4 "
08234 Healer. 9 KW. 600 volt. 3 phase 26 03277 3/4" Ball Valve, manual drain
08241 Healer. 9 KW. 208 volt. 1 phase 27 22221 Solenoid Valve. boiler dram
08242 Heater. 9 KW. 220/240 volt 1 phase 28 13252 Drain Manifold
08243 Heater. 9 KW. 440/480 volt 1 phase 29 45006 Low Water Cut-Off Assembly (California only)
08244 Healer. 9 KW. 600 volt. 1 phase 30 41943 LWCO Mounting Plate (California only)
08165 Heater. 12 KW. 208/220 volt. 3 phase 31 05253 Brass Street Elbow (California only)
08166 Heater. 12 KW. 230/240 volt. 3 phase 32 02623
Reducing Bushing. 1/2" - 1/4' (California only)
08167 Heater. 12 KW. 440/480 volt. 3 phase 33 19995 Float Switch. LWCO (California only
08163 Heater. 12 KW. 600 volt. 3 phase 34 19993 DPDT Power switch
08214 Heater. 12 KW. 208/220 volt. 1 phase 35 19994 SPST Momentary contact reset switch
08215 Heater. 12 KW. 230/240 volt. 1 phase 36 07167 Pressure gauge. 0-30 psi. 1 1/2"
Manufacturer reserves right of design improvement or modification, as warranted.