Repair manual
ELECTRIC STEAM GENERATOR (BOILER) ASSEMBLY
24KW, 36KW, & 48KW (2, 3, & 4 HEATER ELEMENTS) -
REFERENCE
NUMBER
PART
NUMBER
DESCRIPTION
1
43936
Boiler shell only. with legs, hand hole plate assembly, mounting studs tor 3 square-flanged heater elements.
43936
Boiler shell (43937) above, also including two corrosion resistors, sight gauge, three probes and
extensions with cover box.
2
43895
Corrosion resistor, with hanger.
3
40445
Water gauge set with glass.
07108
Fibre washer (2 required)
23132
Gauge glass washer (2 required).
4
07302
Glass only 6" long.
5
40462
Probe with lock washer and screw.
6
101467
Probe extension set (3).
7
40421
Hand hole plate ass'y.. including bar. nut. and gasket.
43748
Hand hole plate-only.
8
07106
Hand hole gasket, flat. 4" x 6" oval.
9
08165
Electric immersion heater, with gasket. 3" flange. 12KW. 208/220 volt, 3 phase.
08166
Electric immersion heater, with gasket. 3" flange. 12KW. 230/240 volt, 3 phase.
08167
Electric immersion heater, with gasket. 3" flange. 12KW, 440/480 volt. 3 phase.
08214
Electric immersion heater, with gasket, 3" flange. 12KW. 208/220 volt. 1 phase.
08215
Electric immersion heater, with gasket. 3" flange. 12KW, 230/240 volt. 1 phase.
08216
Electric immersion heater, with gasket. 3" flange. 12KW, 440/480 volt. 1 phase.
08175
Electri
c
immersion heater, with gasket, 2 1/2' flange, 12KW, 208/220 volt. 3 phase.
08176
Electric immersion heater, with gasket, 2 1/2' flange, 12KW, 230/240 volt. 3 phase.
08177
Electric immersion heater, with gasket. 2% ' flange, 12KW, 440/480 volt, 3 phase.
10
07128
Heater gasket — 3" square.
07115
Heater gasket — 2 1/2 square.
11
53250
Probe cover.
12
03504
Water control relay. 115 volt (1D1DO).
13
03514
Low water cut-off relay, 115 volt, (1C1DO).
14
03276
1
/
4
ball valve water supply shutoff.
15
22102
1
/
4"
check valve.
16
44095
1
/
2"
water feed solenoid valve
17
19870
1/4
line strainer.
18
03509
Contactor — 50 amp.
03506
Contactor — 75 amp.
19
20533
Transformer, 75VA, (All. except Convection Steamers).
20
02193
Heavy duty terminal block — use with more than one contactor (125 amp size)
20A
02196
Heavy duty terminal block — use with more than one contactor (250 amp size).
24KW, 220 volt. single phase and 48KW. 208 220 & 240 volt. three phase.
21
20535
Transformer, 150VA, (Convection Steamers only).
22
03202
Circuit breaker for 20535.
23
19947
Pressure switch (Models after 1-70).
24
22130
Safety valve — 8 psi
22131
Safety valve — 15 psi
25
19968
Reset switch.
26
19944
On-Off power switch. 115/220 volt DPST (before 1-78).
19967
On-Off power switch, 11
5
volt 3PDT (after 1-78) and all auto blowdown.
27
12161
Signal light, 115/220 volt, 1"
12169
Signal light, 115/220 volt, 1/2
'
(Pressure Steamers only).
28
07173
Steam pressure gauge, rear mount. 0-30 psi, 2 1/2.
07168
Steam pressure gauge, rear mount, 0-30 psi, 2" (Pressure Steamers only)
29
03277
Generator drain valve — ball type.
30
22140
Air vent.
31
40471
Control enclosure.
32
52568
Cover, control enclosure.
33
22122
3
/
4'
pressure reducing valve, 3-15 psi output (optional).
34
19945
Float switch with gasket — low water cut off (California only).
35
22104
1/4
'
solenoid valve — boiler condenser water supply.
36
19979
Thermal switch — boiler condenser.
37
22106
Valve, solenoid. 1/2" boiler auto blowdown, 115 volt (optional)
CLEVELAND RANGE CO, 1333 EAST 179th ST., CLEVELAND, OHIO 44110
Manufacturer reserves right of design improvement or modification, as warranted.
- 3 PROBE TYPE 1968
to PRESENT