Service & Parts Manual Convotherm Combination Oven-Steamer MODELS: Electric 10.10 and 6.20 by OES-10.10 OEB-10.10 OES-6.20 OEB-6.20 1333 East 179th St., Cleveland, Ohio, U.S.A. 44110 Enodis Phone: (216) 481-4900 Fax: (216) 481-3782 Visit our web site at www.clevelandrange.
Installation Operating Instructions Cleaning Instructions Service Parts Table of Contents For the Installer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Installation Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Service Parts (continued) Maintenance Table of Contents (continued) Pump, Steam Generator, Electric, (OEB 6.20 & 10.10). . . . . . . . . . . . . . 53 Door (OES 6.20 & 10.10) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Sliding Plate, Complete (all models) . . . . . . . . . . . . . . . . . . . . . . . . . 55-56 Exterior Sheeting (all models) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 Stand, Assembly, Closed Base (all models) . . . . . . . . . . . .
INSTALLATION FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. WARNING I Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment. WARNING Disconnect power at the main external power switch before servicing or repairing a Combi.
Cleveland STATEMENT OF POLICIES LIMITED WARRANTY CLEVELAND RANGE products are warranted to the original purchaser to be free from defects in materials and workmanship under normal use and service for the standard warranty period of one year from date of installation or 18 months from date of shipment, which ever comes first. CLEVELAND RANGE agrees to repair or replace, at its option, f.o.b.
GENERAL INFORMATION ABOUT COMBIS A. PRODUCT INFORMATION Cleveland Range, LLC assigns two product identification numbers to each Combi: a model number and a serial number. The model number identifies the product characteristics. The serial number identifies the individual unit. 1. Model Number a. This manual covers installation of the OEB and OES model electric powered Combis. b.
INSTALLATION INSTRUCTIONS A. GENERAL This equipment should be installed only by qualified, professional plumbers, pipe fitters, and electricians. 1. The installation of this Combi must conform with: a. The National Electrical Code, ANSI/NFPA 70 (latest edition), or the Canadian Electrical Code, CSA C22.2 as applicable. b. The Food Service Sanitation Manual of the Food and Drug Administration (FDA). c. All applicable national, state, and local laws, codes, and regulations. 2.
B. INSTALLATION OF THE COMBI – General Instructions General Instructions: 1. Select the Combi’s operating location. 2. Complete the water, drain, and electric lines before positioning and leveling the Combi. 3. Position and level the Combi. 4. Connect the utility lines after positioning and leveling the Combi. 5. Call Cleveland Range at 216-481-4900 for the Free Start-Up Program’s Performance Checkout. 6. After Setup and Performance Checkout, the Combi should provide years of reliable operation.
C. SPECIAL INSTRUCTIONS FOR CASTER EQUIPPED COMBI STANDS AND COMBIS 1. Read all instructions before beginning installation. 2. Level the floor if needed. 3. NOTE: Combis on caster-equipped stands have less adjustment for level than adjustable foot equipped stands. 4. The front wheels of caster-equipped stands and Combis have locks. Check the caster locks for function and position before installation. 5. Follow the separate instructions included with the Stand, Stacking Kit, or Caster Kit. 6.
SINCE 1922 INNOVATIVE STEAM COOKING SOLUTIONS COMBI OVEN-STEAMER by Featuring the MODEL: c OEB-10.
36.70" The "Advanced Closed System" offers the following advantages: ■ Saves energy ■ Automatic moisture level adjustment ■ Low heat and steam emission to the kitchen ■ Automatically regulated steam injection ■ Enables immediate change into the steam mode ■ "Crisp & Tasty" demoisturizing function 1.82" 1.58" 38.98" 44.98" 2.52" Model: OEB-10.10 Pan Capacity [Unit has 11 slide rails at 2.
SINCE 1922 INNOVATIVE STEAM COOKING SOLUTIONS COMBI OVEN-STEAMER by Featuring the MODEL: c OES-10.
36.70" The "Advanced Closed System" offers the following advantages: ■ Saves energy ■ Automatic moisture level adjustment ■ Low heat and steam emission to the kitchen ■ Automatically regulated steam injection ■ Enables immediate change into the steam mode ■ "Crisp & Tasty" demoisturizing function 1.82" 1.58" 38.98" 44.98" 2.52" Model: OES-10.10 Pan Capacity [Unit has 11 slide rails at 2.
SINCE 1922 INNOVATIVE STEAM COOKING SOLUTIONS COMBI OVEN-STEAMER by Featuring the MODEL: "Advanced Closed System +3" CAPACITY: ELECTRIC HEATED – with Steam Generator c OEB-6.
47.92" The "Advanced Closed System" offers the following advantages: ■ Saves energy ■ Automatic moisture level adjustment ■ Low heat and steam emission to the kitchen ■ Automatically regulated steam injection ■ Enables immediate change into the steam mode ■ "Crisp & Tasty" demoisturizing function 1.82" 1.58" 30.12" 36.12" 2.52" Model: OEB-6.20 Pan Capacity [Unit has 7 slide rails at 2.
SINCE 1922 INNOVATIVE STEAM COOKING SOLUTIONS COMBI OVEN-STEAMER by Featuring the MODEL: "Advanced Closed System +3" CAPACITY: ELECTRIC HEATED – Boilerless c OES-6.
47.92" The "Advanced Closed System" offers the following advantages: ■ Saves energy ■ Automatic moisture level adjustment ■ Low heat and steam emission to the kitchen ■ Automatically regulated steam injection ■ Enables immediate change into the steam mode ■ "Crisp & Tasty" demoisturizing function 1.82" 1.58" 30.12" 36.12" 2.52" Model: OES-6.20 Pan Capacity [Unit has 7 slide rails at 2.
CONTROL PANEL BASIC OPERATION A. QUICK START GUIDE ALWAYS PRE-HEAT THE OVEN CHAMBER! 1. Switch on with key (1). 2. Select cooking mode with keys (2-5). 3. Press key (6) to start. OR 1. Press key (18) and rotate Selector Dial (23) to set oven temperature. 2. Press key (19) and rotate Selector Dial (23) to set cooking time. OR 1. Press key (20) and rotate Selector Dial (23) to set core temperature. ALL 1. Press key (6) to start the Combi. 2.
B. CONTROL PANEL DETAIL VIEW Note: Item numbers correspond to numbers on the control panels in Figure 4-1b 1. ON/OFF When the Combi is turned ON: • Self-diagnosis is performed. • Oven light turns on. • Steam generator fills and heats (OEB and OGB models). Cooking Modes 2. Steam • Oven temperature is continuously variable between 86°F and 248°F. 3. Combi Hot Air and Steam • Oven temperature is continuously variable between 212°F and 482°F. 4.
• Page / Scroll one step forward or back in programming mode. Function Indicators • Light up when function or activity is engaged: 23. Selector Dial 10. Reduced Power 11. Burner or Electric Heating ON 12. Reduced Fan Speed 13. Cooking Mode Engaged 14. Button Lock 15. Crisp & Tasty Engaged 16. Program Protection • Set: Oven temperature, cooking time, core temperature, recipe name, recipe number. • Select Smart Key functions, editing functions and recipes in the cookbook. 24.
AT THE END OF THE DAY OR SHIFT A. Cleaning the Oven Chamber CAUTION Clean the oven chamber at least once per day or more frequently as needed Failure to clean the Combi properly and regularly can cause equipment damage. Damage caused by improper cleaning will invalidate the Warranty! 1. Cleaning – General a. Regular cleaning of the Combi after use, inside and out, helps guarantee many years of satisfaction from your Combi. b. Clean and maintain the Combi ONLY when the Combi is cold. c.
WARNING When working with cleaning agents, nozzle rinsing fluid and spray bottles: Wear suitable clothing, protective gloves and protective goggles to help protect from splashes and spills. Failure to do so can result in chemical burns on skin and in eyes. WARNING Read, understand, and heed and obey all instructions and safety information found on cleaning agent labels, Material Safety Data Sheets, and related documents and sources. Failure to do so can result in death, injury, and equipment damage. 3.
e. Clean the Bypass Measuring Aperture. (Opening in the oven chamber on the left-hand side, slightly below the door latch. See diagram.) 1) Spray with CONVOClean. 2) Rinse clean with the hand shower. f. Remove and clean the drain cover. 1) Clean food residue and drippings from the tray and drain in the oven chamber. 2) Spray on original CONVOClean oven chamber cleaner and allow it to take effect. 3) Rinse thoroughly with the hand shower. g. Clean the drain and make sure that it is not blocked. h.
B. Semi-Automatic Cleaning of the Oven Chamber NOTE: Do NOT press the Start/Stop key while using the Semi-automatic Cleaning process. This stops the cleaning process. WARNING The Semi-Automatic Cleaning process is designed to be started when the oven chamber temperature is at or below 158°F. Death, injury, and equipment damage can result from starting the Semi-Automatic Cleaning process when the oven chamber is above 158°F. 1.
15. 16. 17. 18. a. The third step is Steam mode at 86°F for 1 minute. No action is needed. b. The fourth step is Steam at 212°F for 10 minutes, followed by a Signal Tone. Turn OFF the Combi when the Signal Tone sounds. Use the hand shower to rinse thoroughly the oven chamber, accessories, and behind the fan guard. In the case of severe staining or soiling, repeat the cleaning process. After use or after cleaning, leave the Combi door open.
C. CONVOClean Automatic Cleaning System (optional): NOTES: • Do NOT interrupt the automatic cleaning process. Interrupting and restarting the Automatic Cleaning System with the ON/OFF key may start a 6 minute forced rinsing of the oven chamber to remove any CONVOClean and CONVOCare residue when the ON/OFF key is turned back ON. The Signal Tone sounds at the end of the forced rinsing cycle and the Combi is ON.
3 4 “Strong Soiling” ‘Strong Soiling – Shining+” 2 hours. 2 hours and 45 minutes. 8. Press the Smart Key. 9. “Food inside oven?” appears in the display. 10. If the oven is empty, then answer “No.” 11. Confirm by pressing the Smart Key. 12. “Start auto-cleaning?” appears in the display. 13. Answer “Yes.” 14. Confirm by pressing the Smart Key. 15. The CONVOClean system starts. 16. The instruction “open the door” appears in the display to check the function of the magnetic door switch. 17.
DESCALE STEAM GENERATOR A. GENERAL INFORMATION 1. Steam generators should be descaled at least once a month, depending on scale buildup. If you have serious steam generator scale buildup, a water treatment system should be installed for the steamer. If this is not possible, the frequency of descaling should be increased. 2. Cleveland Range, recommends the use of DISSOLVE® Descaler Solution, Cleveland Range Part Number 106174. No other system of steamer descaling should be used. 3. NOTE: Part No.
DANGER Do NOT heat the Combi during descaling. Death, injury, equipment and property damage can result. WARNING This procedure is slightly different depending on the model being descaled. This entire procedure should be read and fully understand as it applies to the model being descaled, before beginning the actual descaling operation. B. GENERAL SAFETY FOR DESCALING 1. Always wear suitable protective clothing including appropriate gloves, and eye protection. 2.
• While adding liquid to the steam generator through the descaler inlets, pour slowly to avoid overflow. • Wipe up any spills at once to avoid etching. 6. After the automatic fill cycle has ended, turn OFF the Combi with the ON/OFF key, and at the Control Power Service Disconnect switch located below the hand shower. See Figure 6-2. 7.
1010 ELEC GENERATOR W CLEANING Condensate Box o-ring C6015000 44 Washer Arm C2611184 45 17 18 Light Gasket C6015020 46 30 40 25 53 Drip Tray Hose 105279 8 34 32 7 33 51 39 38 36 37 55 40 35 27 50 49 57 54 24 60 48 59 56 5 52 58 4 65 21 3 63 64 11 26 15 19 16 28 47 1 31 43 2 41 29 12 6 42 9 10 61 Spray Handle Shut Off Valve C6014003 62 23 22 20 13 Spray Handle Bracket C2002042 14 Lamp C5005045 28 C3216313 B 0706
1010 ELEC GENERATOR W CLEANING ITEM QTY PART N0.
1010 ELEC INJ W CLEANING Washer Arm C2611184 Condensate Box o-ring C6015000 Spray Handle Shut Off Valve C6014003 Light Gasket C6015020 52 25 Lamp C5005045 20 10 60 4 32 3 28 22 33 1 59 13 48 39 55 14 34 11 48 43 57 17 31 58 56 5 61 15 2 35 26 23 36 51 38 49 6 37 16 9 54 50 Spray Handle Bracket C2002042 30 27 24 53 21 18 Element Flange C8017010 29 19 Element Gasket C6015025 8 42 40 7 41 12 47 46 44 45 Drip Tray Hose 105279 30 C3216313 B 070
1010 ELEC INJ W CLEANING ITEM QTY PART N0.
620 ELECTRIC GENERATOR W CLEANING Washer Arm C2611184 Set of racks with center support FK1119821 Light Gasket C6015020 15 43 61 17 3 22 62 58 26 34 33 63 33 35 42 44 Drip Tray Hose 105279 7 6 52 50 51 23 28 56 53 58 55 57 54 32 21 59 27 60 30 22 11 36 24 4 1 18 2 38 40 29 5 49 48 45 47 46 Spray Handle Shut Off Valve C6014003 16 39 31 20 13 14 Spray Handle Bracket C2002042 12 Condensate Box o-ring C6015000 19 37 9 10 8 Spray arm Valve C601400
620 ELECTRIC GENERATOR W CLEANING ITEM QTY PART N0.
620 ELEC INJ W CLEANING Washer Arm C2611184 Set of racks with center support FK1119821 Light Gasket C2611068 Lamp C5005045 56 17 35 53 14 15 3 22 60 50 20 26 30 1 2 27 34 36 21 50 47 49 46 58 59 45 Drip Tray Hose 105279 22 48 7 44 42 43 6 51 52 24 55 54 61 18 4 28 16 32 23 5 41 40 37 39 38 31 Spray Handle Shut Off Valve C6014003 25 57 11 12 13 Spray Handle Bracket C2002042 29 9 10 Condensate Box o-ring C6015000 19 8 33 Spray arm Valve C6014003
620 ELEC INJ W CLEANING ITEM QTY PART N0.
20 43 36 20 12 28 40 17 29 9 45 38 20 22 10 39 20 43 20 5 12 28 36 12 15 20 28 38 34 17 23 38 6 28 36 18 20 40 20 24 11 19 38 1 2 13 7 8 14 42 46 48 37 35 27 47 6 30 41 25 3 20 31 20 32 26 41 4 22 22 6 22 16 20 21 37 20 33 COMPONENT PANEL ASSEMBLY, ELECTRIC 6.20 & 10.
COMPONENT PANEL ASSEMBLY, ELECTRIC 6.20 & 10.10 MODELS ITEM QTY PART N0.
LIGHT ASSEMBLY ALL MODELS 6 5 3 2 7 1 6 5 4 3 2 1 ITEM 1 1 1 1 4 1 QTY C5005045 C5005043 C8019006 C5015002 C6015020 C5015003 C8002025 C5015001 PART N0.
ASSEMBLY, CONTROL PANEL, WITH PICTO ALL MODELS 2 5 4 11 10 9 1 7 6 3 8 ITEM QTY 1 2 3 4 5 6 7 8 9 10 11 12 1 1 1 1 1 10 1 10 1 1 2 2 1 PART N0.
BASE, ELECTRIC, INJECTOR, NO CLEANING 3 20 8 19 11 10 4 17 1 14 6 1 16 12 7 2 13 5 15 ITEM QTY PART N0. DESCRIPTION 1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 18 19 20 26 27 1 1 1 1 5 4 1 1 1 1 2 1 1 3 4 2 1 1 1 1 1 C2114520 C2216088 C2016023 C5011003 C8006058 C8003035 C5006063 C5006064 C70016603000 C6005021 111538 111522 111551 C8003029 C8013004 C8005021 C5215897 C2114626 C2016039 C700106607000-1 C700106607000 OUTER BASE, EL, 6.10/10.
BASE, ELECTRIC, GENERATOR, WITH CLEANING OEB 10.10 MODELS 2 6 4 11 Bulk head Fitting (clean&rinse fitting)-C6015247 3 7 13 20 Nut for Bulk head C8004060 1 17 9 1 19 15 10 16 8 18 ITEM QTY 1 2 3 4 6 7 8 9 10 11 13 15 16 17 18 19 20 21 23 24 25 26 27 1 1 1 1 1 1 5 4 1 1 1 2 1 1 3 4 2 1 1 1 1 1 1 PART N0.
BASE, ELECTRIC, INJECTOR, WITH CLEANING OES 10.10 MODELS 2 5 21 Clean and Rinse Fitting C6015247 10 Nut for Clean and Rinse fitting C8004060 3 6 12 19 1 16 8 1 18 14 9 15 7 17 ITEM QTY PART N0.
BASE, ELECTRIC, GENERATOR, NO CLEANING OEB & OES 6.20 MODELS 4 11 A 20 17 19 3 21 15 1 10 DETAIL A 16 Pressure switch C5009055 14 12 8 Clean & Rinse Fitting C6015247 7 16 Nut for Clean & Rinse Fitting 9 12 13 ITEM QTY PART N0.
BASE, ELECTRIC, GENERATOR, WITH CLEANING OEB 6.20 MODELS 6 2 13 22 19 3 21 5 A 1 DETAIL A 12 17 18 Pump C5008011 16 10 14 Pressure switch C5009055 9 18 Clean & Rinse Fitting C6015247 11 Nut for Clean & Rinse Fitting C8004060 14 15 ITEM QTY PART N0.
OUTER BASE ALL ELECTRIC 6.10 & 10.10 MODELS 3 1 2 A A 5 6 4 SECTION A-A ITEM QTY PART N0. DESCRIPTION 1 2 3 4 5 6 1 4 1 2 9 2 C2115380 111604 C2114627 C8006058 C8008094 C8003035 WELDMENT, OUTER BASE, ELECTRIC & GAS INJ, 6.10/10.
Oring: 078180-1
ASSEMBLY, WATER HOSE SYSTEM, CONDENSER ALL ELECTRIC 6.20 MODELS Connecter Flange C5011003 1 3 5 4 2 ITEM QTY PART N0. DESCRIPTION 1 2 3 4 5 6 1 2 1 1 1 2 C6015215 111647 11149811000 300362 300407 300509 ELBOW, HOSE CONNECTION, 3/8" WITH SEAL CLAMP, OETIKER, S/S, 19/32" HOSE, SILICONE, 3/8" ID X 11.
G CL E AN IN G M R EA ST RATO E EN ASSEMBLY, WATER VALVE, W/CLEANING SYSTEM OEB 10.10 MODELS 2 DE HU M IDI FIC AT IO N 2 4 2 5 3 1 ITEM QTY PART N0.
ASSEMBLY, WATER VALVE ALL ELECTRIC 6.20 & 10.10 MODELS 2 2 4 5 3 1 ITEM QTY PART N0. DESCRIPTION 1 2 3 4 5 1 2 2 2 4 300457 111498 111647 300407 300509 VALVE ASSY.
ASSEMBLY, WATER VALVE, INJECTOR, ELECTRIC OES 6.20 & 10.10 MODELS 2 7 9 2 8 11 11 5 2 12 3 4 2 10 6 12 3 1 ITEM QTY PART N0. DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 12 1 4 2 1 1 6 1 1 2 4 A/R A/R 300457 111498 C6015401 C5001085 C6006140 111647 C6015232 C5009063 300407 300509 00946 111651 VALVE ASSY. 2 WAY 240VAC HOSE, SILICONE, 3/8" ID (SPECIFY LENGTH) BARB, 1/2 R X 3/8 HOSE PRESSURE REGULATING VALVE OD GAS GAUGE, 60 PSI BOTTOM MOUNT CLAMP, OETIKER, S/S, 19/32" CONNECTION NOZZLE 0.6MM 6.20/10.
ASSEMBLY, WATER SUPPLY, GENERATOR W/CLEANING SYSTEM OEB & OGB 6.20 MODELS STEAM GENERATOR 2 1 2 CLEANING 2 DEHUMIDIFICATION 2 4 2 CLEANING ITEM QTY PART N0.
ASSEMBLY, WATER VALVE OES 6.20 MODELS 4 6 5 4 4 9 11 4 4 8 10 2 7 2 8 4 3 1 ITEM QTY PART N0. DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 1 3 6 5 10 1 1 2 1 1 1 300453 300407 300509 111498 111647 111646 C5001085 C6015401 C6015232 C6006140 C5009063 VALVE ASSEMBLY, 3 WAY 240VAC (OES 6.
6 4 4 FLOW DIRECTION 4 5 ORIFICE COLOR CODE 7 2 8 4 2 2 4 3 1 ITEM 1 QTY 1 2 3 4 5 6 7 8 3 6 7 6 1 2 1 PART N0. 300453 300363 300407 300509 111498 C6016070 111646 C6006086 SEE DRAWING DESCRIPTION VALVE, SOLENOID, 3 WAY, 240VAC VALVE, SOLENOID, 3 WAY, 120VAC FILTER, ELECTRICAL, RC NETWORK, 125 VAC, 200 VDC TERMINAL, SLIPON, INSUL., 18-22 AWG, PIGGYBACK HOSE, SILICONE, 0.375" ID X 0.655" OD CLAMP, HOSE, 0.630" - 0.
REGULATOR ASSEMBLY FK1132281 3.10 FK1132282 FK1132283 6.20/10.10/10.20 FK1132284 12.20 20.
ASSEMBLY, STEAM GENERAT0R, ELECTRIC, HEATER SELECTION OEB 6.20 & OEB-10.10 MODELS 2 3 8 5 1 4 ITEM QTY PART N0. DESCRIPTION 1 2 3 4 5 6 7 8 1 1 1 2 1 1 1 13 C2314217 C2314243 C6015040 C6015023 C5019003 C5017012 C5017013 C8017011 WELDMENT, GEN, ELEC 6.20/10.10 SUPPORT, STEAM GEN, TABLE TOP UNIT FLAT GASKET FOR DOUBLE-LEVEL PROBE FLAT GASKET FOR IMMERSION HEATER ASSEMBLY, DOUBLE LEVEL PROBE ASSEMBLY, IMMERSION HEATER, 6.3 KW, 230V ASSEMBLY, IMMERSION HEATER, 9.
ASSEMBLY, STEAM GENERATOR, ELECTRIC OEB 6.20 & OEB-10.10 MODELS USED ON 6.20 AND 10.10 GENERATOR 1 8 12 7 5 11 4 ITEMS 4 AND 5 MOUNT THE GENERATOR TO THE BODY USED ON 10.10 GENERATOR 1 3 13 6 9 2 10 ITEM QTY PART N0.
PUMP, STEAM GENERATOR, ELECTRIC, 240V PREASSEMBLED OEB 6.20 & OEB-10.10 MODELS 5 1 2 3 4 8 6 7 ITEM QTY PART N0. DESCRIPTION 1 2 3 4 5 6 7 8 1 1 1 1 1 4 4 4 C6015101 C6015100 C6005299 C8009057 300507 111629 111633 C8017008 C8005015 DRAIN ELBOW FOR STEAM GENERATOR SUPPORT BUSHING, STEAM GENERATOR - PUMP WIRE CLAMP D: 36, BLACK DRAIN PUMP, 230 V PUMP BRACKET, GEN, ELEC SCREW, HEX HD, M3 x 16, SST, FULLY THREADED NUT, LOCKING, SERRATED WASHER 3.
DOOR 6.20 COMPLETE OES 6.20 & 10.10 MODELS 4 2 1 3 5 6 7 8 Spring clip C6015248 ITEM QTY PART N0. DESCRIPTION 1 1 1 1 1 1 1 2 1 1 1 A/R A/R C2514358 C2514359 C2514389 C2514390 C6012000 C6009016 C8015000 C2514430 C8001024 C8005021 C7004012 C7003087 ASSEMBLY, OUTER DOOR, 6.20 ASSEMBLY, OUTER DOOR, 10.10 ASSEMBLY, INNER DOOR, 6.20 ASSEMBLY, INNER DOOR, 10.10 DOOR HANDLE, LOCKING PLASTIC LETTER "C" RED MLF SCREW M6X8 UNHINGING SAFEGUARD, DOOR SCREW, FILISTER HD, M4x10 DIN 7985 WASHER, 4.
SLIDING PLATE, COMPLETE ALL 6.20, 10.10 MODELS & 20.20 MODELS Page 1 of 2 Upper Hinge C2013006 E E A B D D C INSTALLED ORIENTATION ITEM QTY PART N0.
SLIDING PLATE, COMPLETE ALL 6.20, 10.10 MODELS & 20.
SLIDING PLATE ASSEMBLY 23 24 13 11 20 17 18 11 7 12 19 9 2 22 3 12 25 15 6 16 21 1 5 8 14 9 4 10 C26148301SERV 0101
SLIDING PLATE ASSEMBLY ITEM 1 QTY 1 2 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 2 2 2 2 2 1 8 2 8 6 2 4 4 2 2 2 4 2 2 4 1 1 2 PART N0. 113069 113070 113071 113072 113073 C2114815 C2114816 C2114817 C2114818 C2114819 C6012017 C6012005 C2014008 C6015226 C6012006 C2013012 C8006057 C8006063 C8006060 C8004057 C8003058 C8003043 C8013002 C8008095 C8001073 C8004040 C8005041 C8005050 C8003066 C8013011 C6012016 C6012008 C2013013 C8015000 DESCRIPTION SLIDING PLATE WELDMENT, 6.
EXTERIOR SHEETING ALL 6.20 & 10.10 MODELS 5 4 3 1 2 ITEM QTY PART N0. DESCRIPTION 1 2 3 4 5 - 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 C2514351 C2514352 C2114652 C2114653 C2114782 C2114783 C2114762 C2114742 C2114763 C2114743 C2115462 C2115452 C2114702 111628 C2115463 C2115453 C2114700 111638 DOOR, 6.20, COMPLETE DOOR, 10.10, COMPLETE WELDMENT, CORNER, FRONT LEFT, 6.20 WELDMENT, CORNER, FRONT LEFT, 10.10 PANEL ASSY, LEFT, OGB 6.20, OGS 6.20, OEB 6.20, OES 6.20 PANEL ASSY, LEFT, OGB 10.10, OGS 10.
STAND, ASSEMBLY, CLOSED BASE 6.10 & 10.10 MODELS Caster Retrofit FK111934 Caster w/brake 111644 Caster w/o brake 111645 11 7 14 15 16 13 1 6 8 12 10 18 2 9 17 4 3 5 ITEM QTY PART N0. DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 1 1 2 2 1 4 1 2 3 24 8 8 8 8 1 1 C3216201 100413 C3216245 C3216249 100241 C3216237 C3216238 111673 111674 110492 104080 111686 111687 110715 23154 14262 110587 111669 WELDMENT, STAND, COMBI, 6.10/10.10 FOOT ASS'Y, ADJUSTABLE (FOR 1.250 SQ.
WR50204 Shims
WR50204 Shims
ASSEMBLY, STACKING KIT, GAS MODELS 6.20 ON 6.20 OR 10.20, 6.10 ON 6.10 OR 10.10, 9 8 18 14 16 15 1 19 12 3 17 5 7 10 4 6 2 12 11 ITEM QTY PART N0. DESCRIPTION 1 2 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4 20 1 1 1 1 1 1 A/R 1 1 C3416377 C3416369 C3416363 C3416361 C2016200 C2016211 C2016212 C3416373 C3417044 C3416372 C3416392 C3416374 C2016204 C2016206 06162 C8001024 05250 05253 14335 108034 111704 111705 00909 111702 111703 WELDMENT, BASE, STACKING KIT, GAS, 6.20/10.
ASSEMBLY, STACKING KIT, ELECTRIC MODELS 6.10 ON 6.10 OR 10.10 12 8 10 3 9 4 13 1 11 2 6 7 6 5 ITEM QTY PART N0. DESCRIPTION 1* 2* 3* 4* 5* 6* 7* 8 9 10 11 12 13 14 1 1 1 1 4 3 1 1 1 1 1 1 1 A/R C3416368 C3416362 C3416365 C2016201 06162 C8001024 111703 05250 05253 14335 108034 111704 111705 00909 WELDMENT, BASE, STACKING KIT, ELECTRIC, 6.10/10.10 SHROUD, STACKING KIT, ELECTRIC, X.10 BRACKET, STEAM EXHAUST PIPE, STACKING KIT, ELECTRIC PIPE, STEAM EXHAUST, ELECTRIC, STACKING KIT FOOT, 6.
CLEVELAND RANGE OEB 6.20/10.10 SEQUENCE OF OPERATIONS When using these instructions refer to the OEB 6.20/10.10 wiring schematic. 1 2 3 When incoming power (220 VAC) is connected to the combi, 220 VAC is sent to a The contacts 2,4 and 6 of the Safety Contactor (KO) b The terminals 2 and 3 of the Control Power Switch (S1) When the Control Power Switch (S1) is turned on (closed) a The red light on the switch is energized. b Incoming power (220 VAC) is sent through the 2A fuse (F1.
• 4 If the ground is not found 220 VAC is sent from terminal 7 on connector X12 on the Control Board (A10) to the fill solenoid (Y3) • The fill solenoid opens and the generator is filled until both probes are grounded. ◊ If the top probe becomes ungrounded for more that 5 seconds the fill solenoid (Y3) will energize.
• c d e For the first 2 minutes 220 VAC is sent from terminal 4 on connector X11 through the normally closed auxiliary contacts of contactor K5 to the K50 contactor coil ◊ K50 contactor closes and the motor turns CW ◊ The normally closed auxiliary contacts on K50 open preventing the K5 contactor from energizing. • For 15 seconds the motor is de-energized and allowed to coast.
5 With the combi in the Hot Air mode with time on the timer, the door closed and the start switch is depressed a The front display will include a lighted bar under the Hot Air symbol • When the heat circuit is energized the heat symbol will be energized • The cooking mode symbol will be energized. • The time display will invert and begin to count down.
◊ 6 The normally closed auxiliary contact of K4 opens preventing the Steam Contactor K1 from energizing • 220 VAC is sent from terminal 7 of connector X11 on the Control Board (A10) to the coil of Contactor K44 until the cabinet reaches the set temperature. ◊ The contactor K44 closes and the third leg of 220 VAC is sent to the 18 KW element (E4) ◊ If the reduced power option is chosen then the K44 Contactor is not energized.
• For the first 2 minutes 220 VAC is sent from terminal 4 on connector X11 through the normally closed auxiliary contacts of contactor K5 to the K50 contactor coil ◊ K50 contactor closes and the motor turns CW ◊ The normally closed auxiliary contacts on K50 open preventing the K5 contactor from energizing. • For 15 seconds the motor is de-energized and allowed to coast.
◊ 7 The contactor K44 closes and the third leg of 220 VAC is sent to the 18 KW element (E4) ◊ If the reduced power option is chosen then the K44 Contactor is not energized. e When the condensate box is heated to 140 degrees F at the B3probe, 220 VAC is sent from terminal 5 of connector X12 to the condenser valve (Y1) until the temperature drops.
• • For 15 seconds the motor is de-energized and allowed to coast. For the next 2 minutes 220 VAC is sent from terminal 3 on connector X11 through the normally closed auxiliary contacts of contactor K50 to the K5 contactor coil ◊ K5 contactor closes and the motor turns CCW ◊ The normally closed auxiliary contacts on K5 open preventing the K50 contactor from energizing. • NOTE: If the door switch (S7) opens by the door opening, then the fan circuit is de-energized.
e f When the condensate box is heated to 140 degrees F at the B3probe, 220 VAC is sent from terminal 5 of connector X12 to the condenser valve (Y1) until the temperature drops. When the timer counts to 0 or the core temp probe (B10) reaches the set amount the cycle ends and the steam generator reverts to the standby temperature of 190degree F.
1 2 3 4 5 6 7 8 A A B B C C D D E E F THIS DESIGN DESCRIBES A PROPRIETARY ITEM AND IS THE PROPERTY OF CLEVELAND RANGE. THIS DRAWING IS NOT TO BE COPIED OR USED WITHOUT THE APPROVAL OF CLEVELAND RANGE. CLEVELAND RANGE, LLC 1333 East 179th St., Cleveland, Ohio 44110-2574 1 2 TITLE VOLTAGE: WATTAGE: CURRENT: WIRING DIAGRAM OEB 6.20/10.10 3 4 70 3Ø 208-240 15.8-20.7KW 45.5-51.8A 5 DRAWN BY DATE REV DRAWING NO.
1 2 3 4 BK 12 5 6 7 8 WIRING DIAGRAM BK 12 L1 BK 8 A BK 12 BK 12 L2 BK 12 L3 BK 8 BK 12 BK 8 /4.A4 A /4.A4 /4.A4 RD 18 /5.C8 -A10:X13:2 /5.F1 /3.B1 3 6.27KW 15.8A (@230VAC) PE BK 14 RD 14 1 2 3 -E4 18KW 45.2A (@230VAC) PE BK 14 RD 14 1 2 3 1 2 3 C BK 14 PE RD 14 OVER TEMPERATURE THERMOSTAT OVEN -B7.1 STB /5.D6 RD 18 22 208/240V -A10:X12:3 -K2 RD 18 -A10:X11:7 -K4 208/240V -K44 208/240V ϑ 5 /5.
1 2 3 4 5 6 7 8 -K11 3 C4 A BK 12 CONTROL POWER -K0:2 3 6 BU 12 -F1.1 YE 18 -B11 -X10:20 -X10 GN 18 SUPPLY MODULE 12VDC RD 18 -X10:A RD 18 -G1 OR 18 32 -A10:X12:1 5 W/BN 18 7 8 PK 18 /5.D6 /2.D8 -K10:3 C RD 18 /5.D5 E6 21 RD 18 D -K55 21 E4 22 E5 21 RD 18 -A10:X11:5 /5.D5 -K56 -K57 21 E4 -A10:X11:4 RD 18 -A10:X11:3 RD 18 /5.D4 208/240V RD 18 RD 18 -K0:A2 FAN LEFT /4.B4 /4.B4 /4.
3 4 /2.A8 /2.A8 BK 12 BK 12 L3 BK 12 /F4 A L1 L2 6 7 8 WIRING DIAGRAM -F10 A 5 /2.A8 5 3 2 1 1 2 4 6 BK 18 BK 18 5 3 1 2 4 6 BK 18 BK 18 5 FAN RIGHT BK 18 /3.E4 1 -K50 FAN LEFT 3 5 2 /3.E4 6 1 -K5 3 BK 18 4 D5 B BK 18 BK 18 13 -Q56 BK 18 RD 18 -X13:3 10A B 14 BK 18 BK 18 /5.
1333 East 179th St., Cleveland, Ohio 44110-2574 2 -B1 BU BU 18 5 4 X14: 3 2 1 RD 18 10 6 7 /3.C3 C RD 18 RD 18 D RD 18 F2 -X10:21 6 5 X13: PUMP/RINSE 4 COMPARTMENT RINSE VALVE 3 STEAM GEN OVER TEMP 2 STEAM GEN PUMP 1 -K0:A1 C /2.B8 RD 18 5 -X10:31 B RD 18 RD 18 GEM FILL/VALVE 4 A RD 18 136 DEHUMIDICATION/VALVE 3 7 PUMP/CLEANING AGENT -X10 RD 18 CONDENSOR/VALVE STEAM GEN STEAM GEN HOT AIR (INNER) 2 -K4:21 MOTOR / SLOW IDM (BL) 6 D RD 18 /2.D7 /3.
L2 2 208/240V RD 2A 4 6 1 1 2 2 L1 L2 L3 1 3 2 2 3 3 3 21 13 4 2 5 3 1 -K55 6 -K0 -K1 -K2 -K4 6 4 2 3 1 5 3 1 1 2 3 5 2 5 4 4 6 6 4 5 1 3 2 6 MAIN CONTACTOR (SAFETY) 2 5 3 1 1W / BN -M1 1V / BU 1U / BK 3Ø 4 2 5 3 1 -F10 5 3 1 (TOP) STEAM GENERATOR (LOWER) 4 1 6 10A STEAM GENERATOR HOT AIR HOT AIR 1 6 -K44 3 5 1 3 2 4 6 2 5 FAN LEFT -K5 4 -K57 6 FAN SLOW 3 -K50 2 5 -K56 4 FAN RIGHT 6 FAN FAST 208/240VAC -X10 2 2 1 1
L2 (RTN) L1 12 12VDC O X2 X1 -K1 21 22 BK SM 5010 CONTROL BOARD 12VDC- FAN (COOLING) STEAM GEN HOT AIR OVEN LAMP L1- 2O8/240-INPUT 1 CONDENSOR/VALVE 2 DEHUMIDIFICATION/VALVE 3 GEM FILL/VALVE 4 MOTOR OVER TEMP 5 MOTOR OVER TEMP 6 MOTOR / LEFT 7 MOTOR / RIGHT 8 MOTOR / FAST 10 9 MOTOR / SLOW X10: 4 3 2 1 8 7 6 5 4 3 2 1 7 6 5 4 3 2 1 HOT AIR 10 11 12 STEAM GEN X12: X17: X16: 12 11 10 9 8 7 6 5 4 3 2 1 14 13 12 11 10 9 RD YL RD YL RD YL RD YL RD YL WH GN G
CLEVELAND RANGE OES 6.20/10.10 SEQUENCE OF OPERATIONS When using these instructions refer to the OES 6.20/10.10 wiring schematic. 1 2 3 4 When incoming power (220 VAC) is connected to the combi, 220 VAC is sent to a The contacts 2,4 and 6 of the Safety Contactor (KO) b The terminals 2 and 5 of the Control Power Switch (S1) When the Control Power Switch (S1) is turned on (closed) a The red light on the switch is energized. b Incoming power (220 VAC) is sent through the 2A fuse (F1.
• c d If the combi fan is in the reduced setting 220 VAC is sent from terminal 6 on connector X11 through the normally closed auxiliary contacts of contactors K55 and K56 to the coil of contactor K57 ◊ The K57 contactor closes Sending 220 VAC through the Q57 thermal overload to the motor and the motor turns at a reduced speed. ◊ The normally closed auxiliary contacts of K57 open preventing the K55 and K56 contactors from energizing.
e 5 When the condensate box is heated to 140 degrees F at the B3 probe, 220 VAC is sent from terminal 5 of connector X12 to the condenser valve (Y1) until the temperature drops. f When the timer counts to 0 or the core temp probe (B10) reaches the set amount the cycle ends.
• 6 220 VAC is sent from terminal 3 of connector X12 on the Control Board (A10) through the normally closed auxiliary contacts of K2 and K1 to the coil of Contactor K4 until the cabinet reaches the set temperature as sensed at probe B6. ◊ The contactor K4 closes and to legs of the 220 VAC is sent to the 18 KW element (E4) • 220 VAC is sent from terminal 7 of connector X11 on the Control Board (A10) to the coil of Contactor K44 until the cabinet reaches the set temperature.
◊ c d e f The K57 contactor closes Sending 220 VAC through the Q57 thermal overload to the motor and the motor turns at a reduced speed. ◊ The normally closed auxiliary contacts of K57 open preventing the K55 and K56 contactors from energizing.
◊ 7 In the light and medium modes (one and two drops in the display) the Y2 valve will be energized until the bypass probe (B5) is satisfied. ◊ In the full mode (3 drops in the display) the Y2 valve will be energized continuously. g When the timer counts to 0 or the core temp probe (B10) reaches the set amount the cycle ends.
• d e f 220 VAC is sent from terminal 3 of connector X12 on the Control Board (A10) through the normally closed auxiliary contacts of K2 and K1 to the coil of Contactor K4 until the cabinet reaches the set temperature as sensed at probe B6. ◊ The contactor K4 closes and to legs of the 220 VAC is sent to the 18 KW element (E4) • 220 VAC is sent from terminal 7 of connector X11 on the Control Board (A10) to the coil of Contactor K44 until the cabinet reaches the set temperature.
1 2 3 4 5 6 7 8 A A B B C C C5008011 D D E E F THIS DESIGN DESCRIBES A PROPRIETARY ITEM AND IS THE PROPERTY OF CLEVELAND RANGE. THIS DRAWING IS NOT TO BE COPIED OR USED WITHOUT THE APPROVAL OF CLEVELAND RANGE. CLEVELAND RANGE, LLC 1333 East 179th St., Cleveland, Ohio 44110-2574 1 2 TITLE VOLTAGE: WATTAGE: CURRENT: WIRING DIAGRAM OES 6.20/10.10 3 4 84 3Ø 208-240 15.8-20.7KW 45.5-51.8A 5 DRAWN BY DATE REV DRAWING NO.
1 2 3 4 5 6 7 8 WIRING DIAGRAM BK 12 L1 BK 8 A BK 12 L2 BK 8 BK 12 L3 BK 8 /4.A4 A /4.A4 /4.A4 RD 18 /5.C8 -A10:X13:2 3 4 1 18KW 45.2A (@230VAC) L1 L2 L3 3 5 1 RD 14 2 4 6 6 BK 14 1 2 3 1 2 3 C RD 18 -E4 PE 2 2 /3.B1 WH 14 BK 8 BK 8 BK 8 -S1:2 D6 /3.A1 WH 14 -S1:5 BU 12 -X10 -K44 D6 BK 12 4 -K4 D8 C 5 5 6 1 3 1 3 -K0 2 B 4 B BK 14 PE RD 14 OVER TEMPERATURE THERMOSTAT STB RD 18 -A10:X12:3 PE RD 18 /5.E3 E /5.F1 /3.B1 /5.
2 3 4 5 A CONTROL POWER -K0:2 -S1 -F1.1 5 BK 18 6 -B11 RD 18 -X10:20 -X10 GN 18 31 FBS2-6 SUPPLY MODULE 12VDC -K11 -A10:X12:1 5 W/BN 18 /5.B8 8 PK 18 /5.D6 /2.D8 -K10:3 RD 18 22 21 22 RD 18 208/240V RD 18 D A1 A1 -K56 -K57 A2 22 RD 18 RD 18 A2 -K55 208/240V RD 18 RD 18 RD 18 /5.D5 RD 18 22 RD 18 208/240V E5 A1 22 A1 208/240V -K55 E6 -K50 A2 -K5 C E5 21 -K57 E4 -K56 -A10:X11:5 /5.D5 RD 18 -K5 E4 E -A10:X11:4 /5.D5 /5.
3 4 /2.A8 /2.A8 BK 12 L2 BK 12 L3 BK 12 7 8 WIRING DIAGRAM 1 -F10 /F4 A 2 4 6 BK 18 RD 18 -X13:3 10A BK 18 A L1 6 5 /2.A8 5 3 2 BK 18 1 BK 18 BK 18 5 3 2 4 6 BK 18 BK 18 5 FAN RIGHT BK 18 6 2 /3.E4 1 -K50 FAN LEFT /3.E4 3 5 1 3 -K5 4 13 D6 B 1 BK 18 -Q56 B 14 BK 18 BK 18 M 3~ 1V / BU /A2 CLEVELAND RANGE, LLC 1333 East 179th St.
COM BU 18 RD 18 B 10 9 CONDENSOR/VALVE DEHUMIDICATION/VALVE HOT AIR (INNER) INJECTION MOTOR / SLOW HOT AIR (OUTER) MOTOR / FAST OVEN LAMP MOTOR / RIGHT L1- 2O8/240-INPUT MOTOR / LEFT -X10:31 MOTOR OVER TEMP -K44:A1 MOTOR OVER TEMP -K56:21 IDM (R) -K57:21 IDM (W) 10 11 12 1 2 3 4 5 6 7 8 IDM (BL) 4 X14: 3 2 1 RD 18 10 8 7 PUMP/CLEANING AGENT -X10 A -X10:31 /3.
1 2 3 4 5 6 7 8 5 1 5 6 FAN RIGHT 1 3 2 4 3 5 6 5 -K50 3 4 3 1 1 2 1 10A -F10 FAN LEFT -K5 3 5 HOT AIR 1 13 21 14 22 C 2.5-4A (3.6A) 5 6 FAN FAST 4 -Q56 13 2 22 14 -Q57 1 18KW 45.2A (@230VAC) 1.6-2.5A (1.
F 1 1333 East 179th St., Cleveland, Ohio 44110-2574 2 THIS DESIGN DESCRIBES A PROPRIETARY ITEM AND IS THE PROPERTY OF CLEVELAND RANGE. THIS DRAWING IS NOT TO BE COPIED OR USED WITHOUT THE APPROVAL OF CLEVELAND RANGE. CLEVELAND RANGE, LLC 3 90 TITLE WIRING DIAGRAM OES 6.20/10.10 4 VOLTAGE: WATTAGE: CURRENT: 3Ø 208-240 15.8-20.7KW 45.5-51.8A 5 DRAWN BY DATE DRL 7-14-05 6 SIZE -Y20 B 1 3 PUMP / RINSE 2 COMPARTMENT RINSE V.