Repair manual

STEP
TEST
RESULT
REMEDY
9.
Remove the short from the HI
and COM terminals on the control board.
Does the AC line
Yes
Reconnect HI & COM wires
and go to Step #10
voltage between WF and L2 stay at 0 vac for
about five seconds, then jump to 120 vac?
No Replace water level control P/N 23198
10.
Yes
Go to Step #12
Drain all water form the generator.
Disconnect the wires
from the LO, HI, & COM terminals at the
control board.
Connect an Ohmmeter across the LO and COM
wires leading to the generator. Does the
Ohmmeter read greater than 100,000 ohms?
No Go to Step #11
11. Disconnect the LO wire at the water sensing
probe on the generator. Does the Ohnmeter
connected in the previous step now read
greater than 100,000 ohms?
Yes
No
Go to Step #12
Replace probe wiring
Yes Go to Step #13 12.
Reconnect the ohmmeter across each end of
the disconnected
LO wire. Does the ohmmeter read less than
10 ohms?
No Replace wire
13. Connect an ohmmeter across the HI and COM
wires leading to the generator. Does the
ohmmeter read greater than 100,000 ohms?
Yes
No
Go to Step #15
Go to Step #14
14. Disconnect the HI wire at the water sensing
probe on the generator. Does the ohmmeter
connected in the previous step now read
greater than 100,000 ohms?
Yes
No
Replace probe wiring
Go to Step #16
Yes
Go to Step #16
15.
Reconnect the ohmmeter across each end of
the disconnected
HI wire. Does the ohmmeter
read less than 10 ohms?
No
Replace probe wiring