Repair manual
Because the chemical is designed to work with no heat applied, the
steam trap on the right side of the new two probe boiler must be closed. Remove the bottom fitting and cap
the outlet side.
STEP #2
Remove the needle valve from the top of the sight gauge located on the front of the generator. This will be the
port of entry for the liquid descaling agent. REMEMBER TO MOVE THE YELLOW HANDLE ON THE WATER
FILL VALVE TO ALIGN WITH THE VALVE BODY. Before applying the descaler, turn on the power switch to
close the drain valve. This will also energize the fill valve.
STEP #3
Using the special funnel and tubing you assembled, squeeze the liquid into the generator through the port the
needle valve was removed from
STEP #4
After the descaling agent has been introduced into the generator, replace the needle valve.
1. Place the lower compartment timer switch in the manual position. As the generator is filling with water,
this will allow any air in the top to escape.
2. To completely fill the generator with water, bypass the water level probe:
a. Remove the black wire at the terminal marked HI on the
water level control board that connects to the water
level probe. b. When the water begins to enter the lower cooking
compartment, CAREFULLY replace the black wire on the
water level control. This will turn the water off.
3. Turn the lower compartment switch back to the timed setting. STEP #5
DO NOT PRESS THE AMBER STEAM SWITCH. THIS CHEMICAL WORKS BEST WHEN HEAT IS NOT APPLIED.
STEP #6
Wait one hour to allow for descaling of the generator. Drain the generator by turning off the red POWER
switch. The drain and fresh water solenoid valves will open for three minutes allowing the generator to flush
out. After draining, fill the generator with fresh water and repeat the flush process by turning off the power
switch.