- Cleveland Pressure Steamer Specifications
(NOT
T
O SCALE)
SECT
.
VI P
AGE
2
0707
Litho in U.S.A.
•
Each compartment has capacity for:
Eight, 12˝ x 20˝ x 2
1
⁄2˝ Cafeteria Pans or
Six, 12˝ x 20˝ x 4˝ Cafeteria Pans or
Four, 12˝ x 20˝ x 6˝ Cafeteria Pans or
Four, 18˝ x 26˝ Bun Pans
•
Many regional, state and local codes exist and it is
the responsibility of the owner and installer to com-
ply with those codes.
•
Cleveland Range equipment is built to comply with
applicable standards for manufacturers. Included
among those approval agencies are: UL, NSF,
ASME/N.Bd., CSA.
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards
whether untreated or pre-treated, based upon 10 hours
of use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million
TOTAL ALKALINITY less than 20 parts per million
SILICA less than 13 parts per million
pH FACTOR greater than 7.5
CHLORINE less than 30 parts per million
Consult a local water treatment specialist for an on site
water analysis for recommendations concerning steam
generator feed water treatment (if required), in order to
remove or reduce harmful concentrations of minerals.
The use of highly mineralized water will mean that more
frequent servicing of the steam generator will be
necessary
.
The fact that a water supply is potable is not
proof that it will be suitable for the generator.
Cleveland Range reserves right of design improvement or modification, as warranted.
KW Volts Watts Ph Amps Wire
24 208
21,500
1
103.4 2
220 24,000 1 109.1 2
240 24,000 1 100.0 2
440
20,200
1 45.9 2
480 24,000 1 50.0 2
208 21,500 3 59.7 3
220
24,000
3
63.1 3
240 24,000 3 57.8 3
440 20,200 3 26.5 3
480
24,000
3
28.9
3
600 24,000 3 23.1 3
360 21,500 3 34.5 4
380
24,000
3
36.5 4
415 24,000 3 33.4 4
KW Volts Watts Ph Amps Wire
36 208 32,200 3 89.5 3
220
36,000 3 94.6 3
240 36,000 3 86.7 3
440
30,200
3
39.7 3
480
36,000
3
43.4
3
600 36,000 3 34.7 3
360 32,200 3 51.7 4
380 36,000 3 54.8 4
415 36,000 3 50.1 4
48 208
42,900
3 119.2 3
220 48,000 3 126.1 3
240
48,000
3
1
15.6
3
440 40,300 3 52.9 3
480 48,000 3 57.8 3
600 48,000 3 46.2 3
360 42,900 3 68.9 4
380
48,000
3
73.0 4
415
48,000
3
66.9 4
ELECTRIC
WATER DRAINAGE CLEARANCE
D
The Floor Drain must be located
outside the confines of the
equipment base
.
1 1/2˝ I.P
.S. common drain.
Do not connect other units to this
drain.
Do not use PVC pipe for drain.
1/4˝ NPT
Cold Water Inlet
35 psi minimum
60 psi maximum
Right - 3”, Left - 3”,
Rear - 3” (12” on control
side if adjoining wall or
equipment is over 30” high
for service access)
Contact factory for
v
ariances to c
learances.