Figure 6 illustrates a typical full-bridge transducer configuration.
LEFT XDCR
8
7
6
3
4
5
2
1
1
2
3
BLK
WHT
BLU
BRN
6
5
4
8
7
WHT
BLU
BLK
BRN
1
1
2
3
4
2
3
4
RIGHT XDCR
CT
TC
CT
TC
Figure 6 – Full-Bridge Transducer Wiring
3.7 M
ATING
C
ONNECTORS
The M12 connector used on the Ultra Series Slim Cell transducer is a four-pin, DC keyed, male connector that mates
directly with the molded corsets offered by Cleveland Motion Controls. The following table lists the pin numbers
and cable colors that apply:
Pin Number Wire Color Signal
1 brown Excitation Voltage
2 white Output – (low going)
3 blue Excitation Return
4 black Output + (high going)
Figure 7 - Front View of M12 Connector
1
2
3
4
When mating the connector, align the keying mechanism and pins so that they enter the socket without you having
to apply excessive force. Use your fingers to sufficiently tighten the coupling nut enough to ensure an adequate seal
and to discourage accidental loosening.
A separate mating connector is available from Cleveland Motion Controls as a convenient field
attachable (insulation displacement) solution if you elect to make your own cables or need to repair
damaged connectors. To order, use CMC part number, X44-34338.
3.8 C
ALIBRATION
For the proper calibration procedure, refer to the Instruction Manual that accompanied your amplifier or tension
controller.