Manual

MAN-70434-0 REV AA ULTRA ISC SERIES SLIM CELL TRANSDUCER
Output Impedance Approximately 64 Ohms per Bridge leg
Maximum Voltage, Gage to
Beam or Base (Ground)
50 Volts peak
Operating Temperature Range 0
o
F to +200
o
F
Maximum RPM 2500 (without derating)
Alignment +/- 2 degrees angular displacement
Break-away torque 0.6 lb-in
1.12 SLIM CELL FORCE RATINGS
Size MWF (lb.) Linear Overload (%)* Ultimate Overload (%) **
10 400 800
25 400 800
50 400 1000
100 300 1000
250 300 1000
UltraSlim 1
500 150 500
500 200 1000
UltraSlim 2
1000 150 500
*Linear overload: Maximum force applied on the transducer before hitting the safety stop (the output is linear up to that
point).
** Ultimate Overload: Maximum force applied on the transducer with out risking permanent deformation.