User guide

MAN-13262
R
EV
BA
DIN
R
AIL
A
MPLIFIER
,
MWI-13262
U
LTRA
1.4 E
NVIRONMENTAL
R
EQUIREMENTS
Requirement Description
Enclosure
IP20
NEMA 1
Operating temperature
0 to 55 degrees C
32 to 132 degrees F
Humidity
Non-condensing
85% at 55 degrees C
85% at 132 degrees F
Altitude
1000 meters
3300 feet
Atmosphere Non-flammable, non-corrosive and dust free
Storage temperature range
-25 to 80 degrees C
-13 to 176 degrees F
Transport temperature range
-25 to 80 degrees C
-13 to 176 degrees F
1.5 O
PERATING
C
ONDITIONS
Condition Ultra Series DIN Rail amplifier
Installation category Category III
Pollution Pollution Degree 2
Input supply Earth (Ground) referenced
Protection Enclosure mounted
1.6 EMC
T
ECHNICAL
R
ATINGS
Port Phenomenon Test Standard Level Test Standard
Enclosure ESD EN 61000-4-2: 8KV AD, 1KV CD EN 61326:1997
Enclosure RF Field EN 61000-4-3 10V/m,1 Khz AM EN 61326:1997
Transducer Leads
Fast Transient
Burst
EN 61000-4-4 1kV EN 61326:1997
Output Leads
Fast Transient
Burst
EN 61000-4-4 1kV EN 61326:1997
Transducer Leads
Conducted
Immunity
EN 61000-4-6 3V/m EN 61326:1997
Output Leads
Conducted
Immunity
EN 61000-4-6 3V/m EN 61326:1997
AC Power Line Surge EN 61000-4-5
+/-2KV L to PE
+/-1KV L to L
EN 61326:1997
AC Power Line Voltage Dips EN 61000-4-11
+/-0.5 Cycle
100%
EN 61326:1997
1.7 E
MISSION SPECIFICATIONS
Port Phenomenon Test Standard Level Generic Standard
Enclosure Radiated EN 61326:
1997
Class A EN 61326:1997
The levels of performance indicated are achieved when the Ultra Series DIN Rail Amplifier is
installed by using the instructions and specifications outlined in this document.
P
AGE
7
OF
26