Owner manual
CLASSIC SERIES AMPLIFIER W/ ISOLATED OUTPUTS MAN-13467 REV CA
Page 8 of 30
1.5 ENVIRONMENTAL REQUIREMENTS
Requirement Description
Enclosure IP20
NEMA 1
Operating temperature 0 to 55 degrees C
32 to 132 degrees F
Humidity Non-condensing
85% at 55 degrees C
85% at 132 degrees F
Altitude 1000 meters
3300 feet
Atmosphere Non-flammable, non-corrosive and dust free
Storage temperature range -25 to 80 degrees C
-13 to 176 degrees F
Transport temperature range -25 to 80 degrees C
-13 to 176 degrees F
1.6 EMC TECHNICAL RATINGS
Port Phenomenon Test Standard Level Test Standard
Enclosure ESD EN 61000-4-2 8KV AD, 1KV CD EN 61326:1997
Enclosure RF Field EN 61000-4-3 10V/m,1 Khz AM EN 61326:1997
Transducer Leads
Fast Transient
Burst
EN 61000-4-4 1kV EN 61326:1997
Output Leads
Fast Transient
Burst
EN 61000-4-4 1kV EN 61326:1997
Transducer Leads
Conducted
Immunity
EN 61000-4-6 3V/m EN 61326:1997
Output Leads
Conducted
Immunity
EN 61000-4-6 3V/m EN 61326:1997
** AC Power Line Surge EN 61000-4-5
+/-2KV L to PE
+/-1KV L to L
EN 61326:1997
** AC Power Line Voltage Dips EN 61000-4-11
+/-0.5 Cycle
100%
EN 61326:1997
** These specifications apply when using CMC power supply, MWI-13418.
1.7 EMISSION SPECIFICATIONS
Port Phenomenon Test Standard Level Generic Standard
Enclosure Radiated EN 61326:
1997
Class A EN 61326:1997
The levels of performance indicated are achieved when the Classic Series DIN Rail Amplifier is
installed by using the instructions and specifications outlined in this document.