Owner manual

CLASSIC SERIES AMPLIFIER W/ ISOLATED OUTPUTS MAN-13467 REV CA
Page 10 of 30
2 SETUP AND CONFIGURATION
2.1 LOAD CELL (TRANSDUCER) TERMINALS
Input Terminal Function Description Notes
J1-1 EXC RET
Supply return for bridge
excitation
Zero voltage terminal for
transducers
COMMON
J1-2 -INPUT
Load cell signal from
transducer 1
Low going output from
transducer
10K ohm line-to-line
J1-3 +INPUT
Load cell signal from
transducer 2
High going output from
transducer
J1-4 +V EXC
Bridge excitation source for
transducers
5.0 Volt or 10.0 Volt supply
terminal,
max. load 100 mA
J1-5 N.C. NO CONNECTION Make no connection
J1-6 N.C. NO CONNECTION Make no connection
J1-7 N.C. NO CONNECTION Make no connection
J1-8 SHLD DRN
Cable shield
drain terminal
Cable Shield for –INPUT and
+INPUT transducer cables
Connect only at amplifier
Transducers (load cells) use strain gages, which have limited insulation levels to ground (earth).
This requires that the COM terminals be connected to ground (earth) to prevent damage to the
transducers (load cells).
2.2 POWER SUPPLY TERMINALS
Supply Terminal Function Description Notes
J2-1 24V RET Power Supply Power supply return
Must not exceed 50 volts
from P.E.
J2-2 +24 VDC Power Supply Positive supply source
+20 to +28 VDC
@ 180 mA max
A fuse with a rating of 0.38A must be used in the 24 VDC supply lead to limit potential
damage to the amplifier in the event of circuit malfunction.
2.3 OUTPUT TERMINALS
Output Terminal Function Description Notes
J2-3 COMMON Output signal return
Common for +/- 10V and
+/-2V output
J2-4 +/- 10V OUT Voltage Output signal
Undamped bi-polar
tension signal
Max. load 2 mA
J2-5 mA MTR RET mA meter signal
Used for current format meter
return
Current through 1 mA
meter returns here
J2-6 METER OUT Output signal
Damped bi-polar tension
signal
Switchable 2.0 V F.S.
or 1 mA F.S.
J2-7 4-20 mA OUT
Current loop Output
signal
Undamped tension signal
current loop source
Internal loop supply
J2-8 4-20mA RET Output current signal
Current return for 4-20 mA
loop
At –15 VDC with respect to
common