Instruction manual

86b_1_5 en bedingt.fm, 02.04.2008 P1885E/EN 2008-04 9
Before initial operation
4
4 Before initial operation
4.1 Ambient conditions
4.2 Air supply
The inside of the air hose must be free of residue; clean it if necessary.
Spray a few drops of light oil into the air inlet tube.
Oils according to DIN 51524 / ISO 3498
4.3 Connect the tool.
Connect the connection couplings to the tool and compressed air line properly.
Activate the compressed air.
Ambient temperature 41 °F (5 °C) to a maximum of +104 °F (+40 °C)
Permissible relative humidity 25 to 90 %, non-condensing
Parameter Data
Air hose Inner diameter 1/2" (ø 12,5 mm),
maximum length 16.4 ft (5 m)
Working pressure range 58 to 101.5 psi (400 to 700 kPa)
Recommended: 90 psi (620 kPa)
Compressed air Air quality according to ISO 8573-1, quality class 2.4.3
The compressed air must be clean and dry.
NOTE
To attain consistent results, maintain a constant working pressure using a 1/2" service unit con-
sisting of filter, pressure regulator and lubricator.
Order no. Packaging
unit
liter
Designation ARAL BP elf ESSO INA Mobil Klüber SHELL
933090 2 HL32
Aralub
EE 100
Energol
HL 32
Polyelis 32
Olna 32
Nuto
H 32
Hydraol
A 32
D.T.E.Oil Light
Vactra Oil Light
Crukolan 32
Molina 32
Molina 22
CAUTION!
The air hose can come off by itself and whip around uncontrollably.
Shut off the compressed air before making the connection.