Instruction manual
86b_1_5 en bedingt.fm, 02.04.2008 P1885E/EN 2008-04 9
Before initial operation
4
4 Before initial operation
4.1 Ambient conditions
4.2 Air supply
➔ The inside of the air hose must be free of residue; clean it if necessary.
➔ Spray a few drops of light oil into the air inlet tube.
Oils according to DIN 51524 / ISO 3498
4.3 Connect the tool.
➔ Connect the connection couplings to the tool and compressed air line properly.
➔ Activate the compressed air.
Ambient temperature 41 °F (5 °C) to a maximum of +104 °F (+40 °C)
Permissible relative humidity 25 to 90 %, non-condensing
Parameter Data
Air hose Inner diameter 1/2" (ø 12,5 mm),
maximum length 16.4 ft (5 m)
Working pressure range 58 to 101.5 psi (400 to 700 kPa)
Recommended: 90 psi (620 kPa)
Compressed air Air quality according to ISO 8573-1, quality class 2.4.3
The compressed air must be clean and dry.
NOTE
To attain consistent results, maintain a constant working pressure using a 1/2" service unit con-
sisting of filter, pressure regulator and lubricator.
Order no. Packaging
unit
liter
Designation ARAL BP elf ESSO INA Mobil Klüber SHELL
933090 2 HL32
Aralub
EE 100
Energol
HL 32
Polyelis 32
Olna 32
Nuto
H 32
Hydraol
A 32
D.T.E.Oil Light
Vactra Oil Light
Crukolan 32
Molina 32
Molina 22
CAUTION!
The air hose can come off by itself and whip around uncontrollably.
➔ Shut off the compressed air before making the connection.