Installation Guide

www.hilti.com
Hilti PROFIS Engineering 3.0.68
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
3
Company:
Address:
Phone I Fax:
Design:
Fastening point:
|
Concrete - Apr 5, 2021
Page:
Specifier:
E-Mail:
Date:
3
4/5/2021
3.1 Steel Strength
N
sa
= ESR value refer to ICC-ES ESR-3187
f
N
sa
³
N
ua
ACI 318-08 Eq. (D-1)
Variables
A
se,N
[in.
2
] f
uta
[psi]
0.08 94,200
Calculations
N
sa
[lb]
7,306
Results
N
sa
[lb]
f
steel
f
N
sa
[lb]
N
ua
[lb]
7,306 0.650 4,749 910
3.2 Pullout Strength
N
pn
= N
p
refer to ICC-ES ESR-3187
f
N
pn
³
N
ua
ACI 318-08 Eq. (D-1)
Variables
N
p
[lb]
7,952
Calculations
-
-
Results
N
pn
[lb]
f
concrete
f
N
pn
[lb]
N
ua
[lb]
7,952 0.650 5,169 910