Installation Guide
Fastener Recommendation 
We recommend RSS Rugged Structural Screws by GRK 
Fasteners (product image shown). Based on their rated loads 
the screw has an allowable steel strength in tension of 1,415lb. 
Utilizing a 200lb point load at the top of a 42” glass panel with 
2 spigots, the tensile load per fastener (1 per spigot) is 1,333lb. 
The GRK RSS 5/16x4 fasteners are strong enough to resist the 
applied load.
This product is available at Home Depot:
• Internet #203525067
• Model #112225
• Store SKU #518167
Part Number
CVGR 316 SSOD48-180 
Satin Finish
Product Name
Round Deck Mount 
Spigot
Spigot Size
1.9” diameter x 7.1” tall
Spigot Weight
5.5 lbs.
Glass Thickness/
Dimensions/Weight 
(per panel)
1/2”/ 60” width x 39.37” 
height/105 lbs.
Accessories 
Included
Base Cover, Rubber 
Gasket
Specifications
 Helpful Installation Tips  
• Mark spigot location on glass panels with a crayon or wax marker. This allows for fast and easier installation of 
  panel in proper location.
• Some clients have suggested screwing the rim joist to the joist as the screws will hold the rim joist tight to the joist 
  where as nails may not.
VERY IMPORTANT 
• 
Apply a bit of lubricant (petrolium jelly) to the inside of the spigot’s black plastic boot where the boot
 meets the   
  glass. The application of lubrication prevents the spigot’s black plastic boot from grabbing the glass panel   
  should you slide/move the glass to adjust its position while in the spigots. 
•  Do not attempt to slide the glass panel while it is in the spigot if there is no lubricant on the black plastic spigot 
  boot as the glass 
panel may stick and fail.
•  If no lubrication is applied to the spigot boot, you must lift the glass panel out of the spigot, adjust its position   
  as desired and then lower the glass panel back into the spigot.
“Do Not Slide Glass 
Panel while in spigots. 
Li the glass panel out 
of the spigots to adjust 
glass panel position“. 
“When glass panel is in 
desired position lower 
glass panel back into 
spigots”. 
Also need to add “Spig-
ots must be in perfect 
alignment with each 
other and fully tighten 
down iso they are xed 
and will not move prior 
to placing glass panel 