Installation Guide
Sheet
X of X
Chris Hartnett &
Associates Preservation
Engineers
521 S. 9th St. #2
Minneapolis, MN 55404
Revisions
#
date
Project #
Scale
Project:
Address:
I hereby certify that this drawing was prepared by me or
under my direct supervision and that I am a duly Licensed
Professional Engineer under the laws of the state of
Minnesota.
Chris A. Hartnett
License # 4237
1
1 of 1
CLEAR VIEW GLASS
RAILING
737 QUENTIN AVE S.
LAKELAND, MN 55403
Connection: (4) 3/8" x
4" lag bolts into (3)
2x10 boards x 10"
long.
For exterior: recommend that
bolt be galvanized or
stainless steel for durability
Spigot
GENERAL NOTES:
1. THIS GUARDRAIL SYSTEM IS IN COMPLIANCE WITH THE 2014 AND 2017
INTERNATIONAL BUILDING CODE (IBC) SECTION 1607.8. IT IS ALSO IN
ACCORDANCE WITH 2015 IBC SECTION 2407 THAT REQUIRES ALL-GLASS
HANDRAILS AND GUARDS BE "LAMINATED GLASS CONSTRUCTED OF
FULLY TEMPERED OR HEAT-TREATED GLASS". 
2. CONNECTION TO DECK SHOWN (4) 3/8" LAG BOLTS THROUGH DECK TO
(3) 2X10 BOARDS, MEETS IBC DECK REQUIREMENTS FOR A 200 POUND
POINT LOAD OR 500 POUND LINE LOAD AT ANY PLACE ON PANEL.
LOADING TO BE EITHER VERTICAL OR HORIZONTAL BUT NOT
SIMULTANEOUS.
2. WHEN THREE SPIGOTS ARE USED, THIS PRODUCT COMPLIES WITH THE
REQUIREMENTS FOR HIGH VELOCITY HURRICANE ZONES (HVHZ).
3. SPIGOTS TO BE 316 STAINLESS STEEL.
4. CONNECTION TO BUILDING VARY BY PROJECT, TO BE DESIGNED BY
PROJECT ENGINEER. CONNECTION TO WOOD STAIR STRINGER IS
DESIGNBED AND SHOWN HEREIN. 
5. THE ABIILITY OF THE EXISTING HOST STRUCTURE TO SAFELY
SUPPORT THE LODS SHALL BE DETERMINED BY THE PROJECT
ENGINEER.
6. MECHANICAL FASTENERS, AS SHOWN. 
36" or 42"
12"
12"
36"
SPIGOT CONNECTION TO GLASS
2 3/8"
1 1/4"
1 1/2"
Connection to base
material varies.
NOTE: Panels in high wind coastal areas require
three spigot, all other areas require two.
Part Number
Product Name
Spigot Size
 Spigot Weight
Glass Thickness/
Dimensions/Weight
(per panel
Accessories
Included
CVGR 316 SSOD48-180
Satin Finish
Round Deck Mount
Spigot
1.9" diameter x 7.1" tall
5.5 pounds
13.5 mm/60" wide x
39.37" tall/ 98.5 pounds
Base Cover, Rubber
Gasket
Wood stringer beyond
CVGR Spigot Attachment to Wood Deck 
(additional instructions)
GENERAL NOTES:
1. CONNECTION TO DECK SHOWN (4) 3/8” LAG BOLTS THROUGH DECK TO (3) 2X10 
  BOARDS, MEETS IBC DECK REQUIREMENTS FOR A 200 POUND POINT LOAD OR 
  50 POUND LINE LOAD AT ANY PLACE ON PANEL. LOADING TO BE EITHER VERTICAL 
  OR HORIZONTAL BUT NOT SIMULTANEOUS.
2. WHEN THREE SPIGOTS ARE USED, THIS PRODUCT COMPLIES WITH THE REQUIREMENTS 
  FOR HIGH VELOCITY HURRICANE ZONES (HVHZ).
3. SPIGOTS TO BE 316 STAINLESS STEEL.
4. 
CONNECTION TO STRUCTURE VARIES BY PROJECT. 
THE ABILITY OF THE EXISTING HOST  
  STRUCTURE TO SAFELY SUPPORT THE LOADS SHALL BE DETERMINED BY THE 
  PROJECT ENGINEER.
5. MECHANICAL FASTENERS, AS SHOWN.
Connection: (4) 3/8” Lag Bolts 
Wood joist beyond