Installation Guide

Fastener Recommendation
We recommend RSS Rugged Structural Screws by GRK Fasteners
(product image shown).
This product is available at Home Depot:
• Internet #203525067
• Model #112225
• Store SKU #518167
Part Number
CVGR 316 SSOD48-180
Satin Finish
Product Name
Round Deck Mount
Spigot
Spigot Size
1.9” diameter x 7.1” tall
Spigot Weight
5.5 lbs.
Glass Thickness/
Dimensions/Weight
(per panel)
1/2”/ 60” width x 39.37”
height/105 lbs.
Accessories
Included
Base Cover, Rubber
Gasket
Specifications
Installation Tips
• Mark spigot location on glass panels with a crayon or
wax marker. This allows for fast and easier installation
of panel in proper location.
Apply a bit of lubricant (petrolium jelly) to the inside of the spigot’s black plastic boot where the boot
meets the
glass. The application of lubrication prevents the spigot’s black plastic boot from grabbing the glass panel
should you slide/move the glass to adjust its position while in the spigots.
Do not attempt to slide the glass panel while it is in the spigot if there is no lubricant on the black plastic spigot
boot as the glass
panel may stick and fail.
If no lubrication is applied to the spigot boot, you must lift the glass panel out of the spigot, adjust its position
as desired and then lower the glass panel back into the spigot.
VERY IMPORTANT •
GENERAL NOTES:
1. THIS GUARDRAIL SYSTEM IS IN COMPLIANCE WITH THE 2014 AND 2017 INTERNATIONAL BUILDING CODE (IBC) SECTION 1607.8. IT IS ALSO IN
ACCORDANCE WITH 2015 IBC SECTION 2407 THAT REQUIRES ALL-GLASS HANDRAILS AND GUARDS BE “LAMINATED GLASS CONSTRUCTED OF
FULLY TEMPERED OR HEAT-TREATED GLASS”. 2. CONNECTION TO DECK SHOWN (4) 3/8” LAG BOLTS THROUGH DECK TO (3) 2X10 BOARDS, MEETS
IBC DECK REQUIREMENTS FOR A 200 POUND POINT LOAD OR 50 POUND LINE LOAD AT ANY PLACE ON PANEL. LOADING TO BE EITHER VERTICAL
OR HORIZONTAL BUT NOT SIMULTANEOUS. 3. WHEN THREE SPIGOTS ARE USED, THIS PRODUCT COMPLIES WITH THE REQUIREMENTS
FOR HIGH
VELOCITY HURRICANE ZONES (HVHZ). 4. SPIGOTS TO BE 316 STAINLESS STEEL. 5. CONNECTION TO BUILDING VARIES BY PROJECT,
TO BE DESIGNED
BY PROJECT ENGINEER.
6. THE ABILITY OF THE EXISTING HOST STRUCTURE TO SAFELY SUPPORT THE LOADS SHALL BE DETERMINED BY THE
PROJECT ENGINEER. 7. MECHANICAL FASTENERS, AS SHOWN.