Specifications

Technical or Setup Assistance
Telephone: 800.945.7730 (USA) or 801.975.7200 (worldwide) • http://www.gentner.com
Audio Perfect
TM
10 Installation and Operations Manual Page 11
If your call is through the handset only (the red OFF LED [4] will be lit), hang up
when the conversation is complete.
AUTO-DISCONNECT NOTE:
If auto-disconnect is enabled (dip switch 5), the AP10 will disconnect upon sensing
loop drop or call-progress tones (depending on the position of dip switch 6).
Remote Connector (DB25) Option
A customer-supplied remote control or contact-closure switch can be used to
perform three functions: mute on/off, system on, and system off. For pinouts,
see Appendix A: Connector Pinouts (Page 17).
Custom Controller Option
The AP products are designed to function with serial custom control systems.
The controller is connected to the AP800 RS232 port. Via the G-Link network,
all AP products can be accessed and controlled from that single point.
Via the custom controller, the AP10 can be turned on or off; transmit and receive
audio can be muted; DTMF tones can be generated (See Appendix B: Touch-
Tone Dialing, Page 19); receive audio volume can be raised or lowered; the
AP10’s binary address can be queried; telephone hybrid can be renulled; input
and output can be metered; and ERL and ERLE can be read. These commands
are also available in the AP Tools software which communictates with the AP10
via an AP800 RS232 serial port and the G-Link LAN.
When Not in Use
The AP10 is inactive when the red OFF LED [4] lit.