- ClearOne Communications Installation & Operation Manual Telephone Interface AP10

25
Appendices ~ Appendix C: Serial Commands
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
LVL
This command reports back the transmit or receive level for a unit.
Command form:
DEVICE
LVL
<CH>
Explanation:
<CH> is which parameter to be measured.
CH=RXIN Parameter for level from the telephone line
CH=RXOUT Parameter for level from the AP10
CH=TXIN Parameter for level into the AP10
CH=TXOUT Parameter for level to the telephone line
Return values:
LVL will return the output level of the line channel in the same
format as the command.
Example:
If the current level for RXIN channel is -20dBu, the following is
returned out the serial port: DEVICE LVL RXIN -20
MUTE
This command controls or reports the mute status of a channel.
Command form:
DEVICE
MUTE
<CH> <X>
Explanation:
<CH> is the channel(s) to be muted/unmuted.
CH=T Parameter to apply to the transmit channel
CH=R Parameter to apply to the receive channel
CH=* Parameter to apply to both channels
<X> is the action (i.e. mute, unmute, report the mute state).
X=0 Set mute to off
X=1 Set mute to on (mute the selected channel)
X=2 Parameter to toggle the state from one state to the other
(regardless of current state)
X=NULL Report the current state of mute for the selected channel
Return values:
MUTE returns the mute status in the same format as the
command.
Example:
If current state of mute for channel T is muted, the following is returned out the
serial port: DEVICE MUTE T 1
If current state of mute for channel T is unmuted, the following is returned out the
serial port: DEVICE MUTE T 0