Owner manual

ClearCube Product Manual and Installation Guide Appendix A – Specifications • 113
Appendix A – Specifications
Table 14 BackPack Specifications
Connections
Hot-swappable modules provide Ethernet, C/Port, and USB connections (R4300)
8-slot chassis
Backwards compatible with Direct Connect or Blade Switching BackPack (R4300)
Fit 14 Cages (112 PC Blades) in a single 42U rack or cabinet
Four exhaust fans located in rear (340 CFM total)
Rear power connection
Audible Noise
< 90dB
Dimensions
3U (5.25" high, standard 19" rack width)
17.0"(w) x 5.25"(h) x 29.8"(d)
Power Input
100–240 VAC, 50/60 Hz, dual redundant PSUs
Power supplied to each individual PC Blade slot
1440 W power required per full Cage (max.)
4900 BTU heat generation per hour per full Cage (max.)
12 Amps current required per full Cage (at 120 VAC) (max.)
AC Input Fuse
T15A, 250V (5x20 mm slow-acting 15 amp fuse)
R4300 CAUTION
DOUBLE POLE/NEUTRAL FUSING
Weight
DCBP/BSBP: 36 lbs (Cage + BackPack), 76 lbs (with 8 PC Blades)
R4300: 42 lbs (Cage + BackPack), 85 lbs (with 8 PC Blades)
Environment
Rack mounted, 0–35º Celsius (C)
Table 15 C/Port Specifications
Connections
VGA monitor connection (standard DB-15)
RJ-45 for PC Blade connection
Requires full CAT5-type cable with all four pairs connected straight through
Power connector
2 powered USB Ports
PS/2 Mouse and Keyboard Ports
Audio Out (34 ohm headset or amplified speaker system required)
Audio In
Dimensions
1.3"H x 5.1"D x 7.7"W
Environment
Stationary installation, 0–50º C
Max. Distance
200 m (660 ft.) CAT5, CAT5e
100 m (330 ft) CAT6
NOTE: For Admin C/Ports, the distance is reduced by half when 9 or more Cages
are attached to a single Admin Daisy Chain.
Power Adapter
Input 100–240 VAC, 50/60 Hz
Output 5VDC 3A