User`s guide

80 • Troubleshooting R Series Data Center Products Users Guide, Rev. B
Troubleshooting
If you have any problems with your system, please check the following items prior to
calling for support.
No power to PC blade
Check the power button on the front of the PC blade.
Verify that the power circuit to the chassis is operational.
Check all power strips, UPS, and extension cords to make sure they are in
working order.
No video or link lights at desktops and no power to blades
R4300: Have a qualified service technician check the fuse.
Chassis power does not come on
R4300: Have a qualified service technician check the fuse.
Video link shows red at blade but green on C/Port
The switch matrix in the R4300 chassis may be in a partially switched condition.
Switch the affected blade to the Admin C/Port and then back.
Fiber Optic Troubleshooting
No video and/or digital link present
Check all the C/Port and fiber optic cables and their associated jacks for signs of
damage or wear. Replace any suspicious cables with new, commercially
manufactured cables and test the remaining cables with a quality tester.
Non-commercial cables are frequently the culprits when equipment fails to work
properly. For this reason, ClearCube strongly discourages the use of
Non-commercial cables.
Check that the power supply brick is the proper one for the Fiber C/port. It should
have a rated output of +5 VDC, 7 A; –5 VDC, 1 A. The power supply for the
standard C/Port and the MVX does not work with the Fiber C/Port.
CAUTION: DOUBLE POLE/NEUTRAL FUSING
The DIM employs fuses in both the neutral and hot lines.