Instruction manual
Clear-Com Communication Systems
ICS-2003 Intercom Panel Instruction Manual
4-3
TEMPERATURE
Operating between 0 and 50 C (32 to 125 F)
Storage between 0 and 70 C (32 to 150 F)
HUMIDITY
Operation and Storage Between 20% and 90%,
Non-Condensing
PACKAGE DIMENSIONS
Height 3.5 in. (8.89 cm), (2 RU, EIA rack)
Width 19.0 in. (48.26 cm)
Depth 6.75 in. (17.15 cm)
Weight 7.5 lbs. (4.0 kg)
OPT-100 AUXILIARY AUDIO I/O OPTION
AUDIO
Output Signal Levels 0.0 dBu nominal
Impedance 600 Ohms, transformer balanced
Frequency Response 100 Hz to 10 kHz, +/- 2 dB of
microphone preamp or external
program input
Distortion Less than 0.5% THD
SA RELAY
Contact Type 1 pair SPDT (single form C)
Contact Voltage Rating 24 VDC
Contact Current Rating 1 Amp continuous, 2 Amps peak at 24
VDC
Notice About Specifications
While Vitec Group Communications makes every attempt to maintain
the accuracy of the information contained in its product manuals, that
information is subject to change without notice. Performance
specifications included in this manual are design-center specifications
and are included for customer guidance and to facilitate system
installation. Actual operating performance may vary.