• EMC:
To satisfy electromagnetic disturbance standards (EN-55022) it may be necessary,
depending on cable length, integration situation and housing construction, to use
damping ferrites on the connection cables ore adequate shielding methods.
•
External light:
For position measurement inside the device IR light sensors are used. These have
integrated protection against external light interference, which should be sufficient
for most applications in normal light conditions. However, to prevent malfunction,
particularly in the presence of direct sunlight, you should take care that there is
sufficient protection against external light.
• Acoustic insulation:
Appropriate vibration dampers are available for noise-sensitive applications. Please
note that fitting these dampers affects the height of the printer mechanism and also
the card-movement level.
•
Excess-current cut-out:
The OEM Module has no integrated excess-current cut-out.
Use appropriate excess-current-cut-out at power supply side.
OEM-User Manual page 8 /19