User manual
CLEARjet GmbH CX-one
9. PIN ASSIGNMENT
ST3 CPU-Board
1 +24V 24V Power Supply
2 +24V 24V Power Supply
3 +24V 24V Power Supply
4 +24V 24V Power Supply
5 +24V 24V Power Supply
6 +24V 24V Power Supply
7 GND Power Supply GND
8 GND Power Supply GND
9 GND Power Supply GND
10 GND Power Supply GND
11 GND Power Supply GND
12 GND Power Supply GND
Power Supply
DB9 male - PIN1 13 n.c.
PIN6 14 loop to Pin 19 Deactivate Handshake from PC
PIN2 15 RXD0 Receive Data Input
PIN7 16 RTS0 Request To Send Output
PIN3 17 TXD0 Transmit Data Output
PIN8 18 n.c.
PIN4 19 loop to Pin 14 Deactivate Handshake from PC
PIN9 20 n.c.
PIN5 21 GND Signal Ground
RS-232 HOST
DB9 male - PIN1 22 DCD1 Data Carrier Detect Input
PIN6 23 DSR1 Data Set Ready Input
PIN2 24 RXD1 Receive Data Input
PIN7 25 RTS1 Request To Send Output
PIN3 26 TXD1 Transmit Data Output
PIN8 27 CTS1 Clear To Send Input
PIN4 28 DTR1 Data Terminal Ready Output
PIN9 29 RI1 Ring Indicator Input
PIN5 30 GND Signal Ground
RS-232 CHIP
31 D+ Data Line
32 D- Data Line
33 VBUS Power Supply from Bus
34 GND Signal Ground
USB
ST7 CPU-Board
1 FEED1 Open Drain Output max. 200mA
Option 1 2 FEED2 Open Drain Output max. 200mA
3 IN1 Input / TTL Level
4 IN2 Input / TTL Level
5 VCC 5V Power Supply Out
6 +24V 24V Power Supply Out
7 GND Signal and VCC Ground
8 GND Signal and VCC Ground
HOPPER
OEM-User Manual page 18 /19