User manual
CLEARjet GmbH CX-one
Write magnetcode JIS I <ESC>$Mw2[n][mmm]{ DATA}
Description
Write magnetcode – JIS I Standard.
[n] = 1 select JIS I Track 1 (max. 79 alphanumeric char
incl. 3 control characters)
[n] = 2 select JIS I Track 2 (max. 40 numeric char
incl. 3 control characters)
[n] = 3 select JIS I Track 3 (max. 107 numeric char
incl. 3 control characters)
[mmm]... number of write databytes
Note: For this command is a special hardware necessary!
After the writecycle the printer returns an acknowledge.
No verification of written data is done. See appendix for
char.table.
ASCII – Code
<ESC>$Mw2[n][mmm]{DATA}
HEX – Code
1B 24 4D 77 32 [n][mmm]{DATA}
Example
<ESC>$Mw210100123456789
Write 10 byte data (0123456789) to JIS I Track 1
Response: + Data written
Write magnetcode JIS II <ESC>$Mw31[mmm]{DATA}
Description
Write magnetcode – JIS II Standard.
[mmm]... number of write databytes (max. 72 char
incl. 3 control characters)
Note: For this command is a special hardware necessary!
After the writecycle the printer returns an acknowledge.
No verification of written data is done. See appendix for
char.table.
ASCII – Code
<ESC>$Mw31[mmm]{DATA}
HEX – Code
1B 24 4D 77 33 31 [mmm]{DATA}
Example
<ESC>$Mw310100123456789
Write 10 byte data (0123456789) to JIS II
Response: + Data written
Programmers Manual Page 46 / 53