Partial erase <ESC>$a[l][mm][nnn][oo][ppp]
Description
This command erases and prints a defined rectangle within
only one operating-cycle (Maximum width is 15 units in x
direction).
[l] = 0 disable permanent partial erase,
send
no additional parameter in this case!
[l] = 1 enable permanent partial erase and store x/y
positions for repetitive use
[l] = 2 enable partial erase for the following
printing-cycle only
[mm] , [oo] valid values for x-position parameters depend
on the used printhead:
DK 200-1: x-position 00 - 48
DK 300-1: x-position 00 - 72
[nnn] , [ppp] values for y-position parameters: 100 - 999
Parameter limits: [oo] – [mm] ≤ 15
[mm] < [oo], [nnn] < [ppp]
Note:
• Send ‘partial erase’ as last command of print-job,
directly before start printing command <FF>
• In case of parameter [I]=1 the selected x/y positions
are stored permanently to the EEPROM.
Use parameter [I]=0 for reset.
• This command is available at firmware version
CX 000804 or later
Greyscale modus not possible.
ASCII – Code
<ESC>$a[l][mm][nnn][oo][ppp]
HEX – Code
1B 24 61[I][mm][nnn][oo][ppp]
Example
<ESC>x12
; text position x
<ESC>y750 ; text position y
25-02-03
; text
<ESC>$a11030020900
; partial erase command
<FF>
; start printing
20
erased area
25-02-03
[ppp]
[oo]
[mm]
print
direction
0
[nnn]
10
30
40
48
990 400 300 200 100 000