User manual

CLEARjet GmbH CX-one
Reset <ESC>r[n]
Description
Usage at normal printer mode:
[n]=1:
Reset all parameters to default values and clear
the printer buffer
[n]=2:
clear the printer buffer
____________________________________________
Usage at error state:
a warm start is executed.
Note: Send no parameter [n] in Error state!
ASCII – Code
<ESC>r[n]
HEX – Code
1B 72 [n]
Example
<ESC>r2
Clear Printerbuffer (if no Error)
Reboot <ESC>$R
Description
Initiates a warm start
ASCII – Code
<ESC>$R
HEX – Code
1B 24 52
Read counters and S/N <ESC>%O[n]
Description
Read out the extended status of the printer.
Parameters [n]:
1: Cyclecounter Printer Mechanism
Return-Format: min. 1char + <CR> max. 10char + CR
2: Cyclecounter Printhead
Return-Format: min. 1char + <CR> max. 10char + CR
8: Serialnummer Printhead
Return-Format: 14char. + <CR>
A: Serialnummer Printer
Return-Format: 10char. + <CR>
D: Printheadtype
Return-Format: 1char. + <CR>
1...DK200-1; 2...DK200-2; 3…DK300-1
ASCII – Code
<ESC>%O[n]
HEX – Code
1B 25 4F [n]
Example
<ESC>%O1 Read the number of already printed
cards
2226<CR> Response from printer
Programmers Manual Page 22 / 53