User manual
CLEARjet GmbH CX-one
4 PRINTER CONFIGURATIONS
4.1 Using the DIP-Switches
Using the DIP-Switches you can alter various printer settings. Here is a summary of
possible options:
DIP Switch Function
Baud Rate
S 1 - OFF
S 6 - OFF
9600 baud
S 1 - ON
S 6 - OFF
38400 baud
S 1 - OFF
S 6 - ON
38400 baud
S 1 - ON
S 6 - ON
57600 baud
Print Energy
S 2 - OFF
S 3 - OFF
Material type 1 RICOH TC-stripe
S 2 - ON
S 3 - OFF
Material type 2 RICOH TC-full-surface
S 2 - OFF
S 3 - ON
Material type 3 MITSUBISHI LEUCO
S 2 - ON
S 3 - ON
Material type 4 RICOH LEUCO
Erase Energy
S 4 - OFF
S 5 - OFF
Material type 1 RICOH TC-stripe
S 4 - ON
S 5 - OFF
Material type 2 RICOH TC-full-surface
S 4 - OFF
S 5 - ON
Material type 3 MITSUBISHI LEUCO
S 4 - ON
S 5 - ON
Material type 4 RICOH LEUCO
Printer Mode
S 7 - OFF Standard printer mode
S 7 - ON Test mode active
Load Firmware
S 8 - OFF Standard printer mode
S 8 - ON Load firmware active
(hardware boot mode)
WARNING
:
You should only alter the settings when the printer is switched off.
User Manual page 28 / 40