Specifications

www.clearcom.com
Americas and Asia-Pacic Headquarters California, United States Tel: +1.510.337.6600
Europe, Middle East and Africa Headquarters Cambridge, United Kingdom Tel: +44 1223 815000
China Oce Beijing, P.R. China Tel: +86-10-65811360/65815577
© 2011. Clear-Com LLC. All rights reserved. ® Clear-Com, the Clear-Com logo, and Clear-Com Encore are registered trademarks of HM Electronics.
Clear-Com Encore
TM
PS-702 Two-Channel Intercom Power Supply
Technical Specications:
dBu is an absolute measurement. 0 dBu is
referenced to 0.775 volts RMS
Program Line Input
Maximum Level before Clipping: >= 20dBu
Input Impedance: >= 5KΩ
Frequency Response
Program Input - Party Line: 200 - 20KHz ± 3dB
Max Distortion
Program Input - Party Line: <= 0.2%
Noise
Program Mic Input - Party Line: < -70dBu
Max Gain
Program Input - Party Line: >= -16dB
Min Gain
Program Input - Party Line: <= -20dB
Mains Power
Input Voltage Range: 100 - 240 VAC
Input Frequency Range: 50 - 60 Hz
Input Power: <= 60 VAC
Output Voltage: 30 VDC ± 0.5V
Output Current per Channel
(Continuous): 1.2 A
Output Current per Channel
(Peak): 2 A (Do not exceed
the 1.2A rating for
more than 2 seconds
per 1 minute period)
Short Circuit Recovery Time
(1st short): <= 0.5 sec
Short Circuit Recovery Time: >= 20 shorts in
20sec) <= 20 sec
Station Capacity
Up to 40 RS-601 beltpacks or 10 speaker stations or
12 headset stations distributed over both channels
Rear Panel Connectors
Intercom: (6) XLR-3M (3 per
channel)
Program: (1) XLR-3F
AC Power: IEC 320 connector
Rear Panel Controls
(2) Termination On-O switches
(1) Volume control
Front Panel Connectors
Intercom (1) XLR-3M
Front Panel Controls & Indicators
(1) Intercom channel switch
(1) A+B link switch
(2) Program switch
(2) Send level controls
(1) Test tone switch
(2) Overload LEDs
(1) Link indicator LED
(1) Power indicator LED
(1) Power switch
Environmental
32˚ - 122˚F (0˚ - 50˚C)
Dimensions
19 in. W x 1.75 in. H x 7.5 in. D
(483 mm x 44 mm x 190 mm)
Weight
6.16 lbs. (2.80 kg)
Notice About Specications
While Clear-Com makes every attempt to maintain the
accuracy of the information contained in its product
manuals, that information is subject to change without
notice. Performance specications included in this manual
are design-center specications and are included for
customer guidance and to facilitate system installation.
Actual operating performance may vary.
PS-702 Back Panel
CHANNEL A
TERM
A
PS-702
CHANNEL B
TERM
B
ON
OFF
ON
OFF
PROGRAM INPUT
LEVEL
ADJUST
22