User guide
65 Tempest®24 00 4-Channel Wireless Intercom System
Master Mode
Master Mode is a Tempest BaseSta on func on that allows mul ple BaseSta ons to share audio without the presence of an
external hardwired intercom system power supply. Master Mode provides the necessary system termina on to the 2-Wire
hybrid circuitry in each of the Tempest BaseSta ons, so that common audio transfer can take place. Each BaseSta on in a
linked system provides its own power for audio. Either a single channel or all channels can be linked.
The only limit to the number of BaseSta ons that can be linked to share an audio channel is the impact of mul ple RF
sources in close proximity. As the number of BaseSta ons goes up and they begin to compete for RF spectrum, the range
will begin to decrease. See the sec on on Accu-Sync and the sec on on Antenna Loca on, to minimize the e ect of RF
compe on.
It is necessary to use Master Mode when two or more Tempest BaseSta ons will be linked to share audio, and an external
hardwired intercom system is NOT present to provide power. When an external 2-Wire intercom system is connected to
Tempest, the external 2-Wire intercom system provides the required power and system termina on and Master Mode is
automa cally disabled.
On the BaseSta on that will be set to Master Mode, set the 2-Wire Intercom Type Select slide switches to the Clear-Com
posi on. Master Mode only works in Clear-Com mode. If “RTS” or “BAL” is selected, an a empt to set the BaseSta on as
master will result in an error message. If the slide switch is changed from Clear-Com to RTS or BAL, Master Mode will turn
OFF, and it will be necessary to return to the “Mul -Base Se ng” menu to re-enable Master Mode.
On slave BaseSta ons, set the slide switches to Clear-Com.
On each BaseSta on, set the shared intercom channel(s) to the 2-Wire mode. Master Mode only works for channels
selected for 2-Wire connec on.
Connect the appropriate intercom channel(s) of each BaseSta on that will share audio using the 3-pin XLR male and female
connectors on the back of the BaseSta on.
Complete all se ngs and connec ons before ac va ng Master Mode. Set one BaseSta on to Master Mode. Master Mode
se ngs are found at the “Set Base as Master” screen under the “Mul -Base Se ngs” main menu selec on. It is only
possible to set one BaseSta on as Master. The words “Master Mode” appear in the top line of the BaseSta on display,
to the right of the BaseSta on name, when Master Mode is ac ve. An a empt to set a second BaseSta on as master, will
result in an error message. It does not ma er which BaseSta on in a linked series is set to Master Mode.
Slave BaseSta ons – those not set as master – detect the master BaseSta on as a Clear-Com connec on.
An a empt to set a BaseSta on to Master Mode while connected to a 2-Wire system, will result in an error message. If a
BaseSta on has “Set Base As Master” rst turned ON, and an external hardwired intercom system is connected later, the
Tempest BaseSta on will turn OFF Master Mode.
The “Set Base As Master” se ng will remain ON through a power cycle.