Instruction Manual

77 Tempest®24 00 2 -Channel Wireless Intercom System
Bu ons on the BeltSta on do not func on
A number of bu ons on the BeltSta on can have alternate func ons that the user can select.
If a bu on on the BeltSta on is not working as expected, re-con rm all se ngs and any alternate func on assignment
in the menu. The bu on may have been reassigned wirelessly from the BaseSta on or by T-Desk. Con rm that the
func on is available for use. If the reassignment involves any GPO, con rm that menu selec on, the connec ons, and
the equipment func onality.
Call Func on does not work properly
Check to make sure that the CALL func on is enabled.
Con rm that a TALK bu on is enabled for the channel that you wish to call.
A Call signal will be received by the BeltSta on only on the channel(s) that are currently being monitored.
Stage Announe (SA) func on does not work properly
The Stage bu on has two separate func ons. Op onally, it controls the shared Stage relay contact on the back of the
BaseSta on.
» When you press the STAGE bu on it reroutes the BeltSta on users microphone to the SA output on the back of
the BaseSta on.
» When pressing the STAGE bu on, if there is no audio present at the SA, con rm that the Stage Announce
func on is enabled in the BeltSta on.
» If the SA relay does not close, ensure that the Stage Relay is enabled in the BeltSta on. If problems persist,
con rm the opera on with another BeltSta on.
Tempest Remote Transceiver
Remote Transceiver RX or TX LEDs do not light
While the Transceiver is properly connected to the BaseSta on, turn the BaseSta on Power Switch to the OFF posi on.
Wait for 30 seconds and turn the BaseSta on Power Switch back to the ON posi on. This should ini alize the Remote
Transceiver. The Con g LED should light momentarily and then go out. Once the Con g LED goes out the Remote Transceiver
TX LED should light. If there are BeltSta ons communica ng to the BaseSta on through the Remote Transceiver the RX LED
should light as well.
When connec ng any shared BaseSta ons to any wired intercom system,
only channels connected to the wired system can be shared. A BeltSta on
CALL signal is sent only when the Talk bu on is enabled.
To manually re-ini alize the Transceiver, power OFF the BaseSta on for at least
15 seconds and power the BaseSta on back ON, with the Transceiver connected.