77 Tempest®24 00 2 -Channel Wireless Intercom System
Bu ons on the BeltSta on do not func on
A number of bu ons on the BeltSta on can have alternate func ons that the user can select.
If a bu on on the BeltSta on is not working as expected, re-con rm all se ngs and any alternate func on assignment
in the menu. The bu on may have been reassigned wirelessly from the BaseSta on or by T-Desk. Con rm that the
func on is available for use. If the reassignment involves any GPO, con rm that menu selec on, the connec ons, and
the equipment func onality.
Call Func on does not work properly
• Check to make sure that the CALL func on is enabled.
• Con rm that a TALK bu on is enabled for the channel that you wish to call.
• A Call signal will be received by the BeltSta on only on the channel(s) that are currently being monitored.
Stage Announe (SA) func on does not work properly
The Stage bu on has two separate func ons. Op onally, it controls the shared Stage relay contact on the back of the
BaseSta on.
» When you press the STAGE bu on it reroutes the BeltSta on user’s microphone to the SA output on the back of
the BaseSta on.
» When pressing the STAGE bu on, if there is no audio present at the SA, con rm that the Stage Announce
func on is enabled in the BeltSta on.
» If the SA relay does not close, ensure that the Stage Relay is enabled in the BeltSta on. If problems persist,
con rm the opera on with another BeltSta on.
Tempest Remote Transceiver
Remote Transceiver RX or TX LEDs do not light
While the Transceiver is properly connected to the BaseSta on, turn the BaseSta on Power Switch to the OFF posi on.
Wait for 30 seconds and turn the BaseSta on Power Switch back to the ON posi on. This should ini alize the Remote
Transceiver. The Con g LED should light momentarily and then go out. Once the Con g LED goes out the Remote Transceiver
TX LED should light. If there are BeltSta ons communica ng to the BaseSta on through the Remote Transceiver the RX LED
should light as well.
When connec ng any shared BaseSta ons to any wired intercom system,
only channels connected to the wired system can be shared. A BeltSta on
CALL signal is sent only when the Talk bu on is enabled.
To manually re-ini alize the Transceiver, power OFF the BaseSta on for at least
15 seconds and power the BaseSta on back ON, with the Transceiver connected.