59 Tempest®900 4-Channel Wireless Intercom System
When an external 2-Wire hard wired intercom system IS present:
Set the 2-Wire Intercom Type Select Switch to the proper type and select 2-Wire mode. Connect the hard wired
intercom to the BaseStaon. In this conguraon, each connected Tempest BaseStaon intercom channel will receive
power and terminaon from the wired intercom system. The Tempest BaseStaon funcons as an addional wired
BeltStaon from the perspecve of the connected 2-Wire system.
Connect either male or female (male and female connectors are electrically idencal) 3 pin XLR from the 2-Wire
intercom channel to be shared, to the BaseStaon that will use the intercom channel. Loop to other BaseStaons
as needed. Repeat for all channels to be shared. See the Wired Intercom Interface secon in this manual for more
informaon about connecng to external wired intercom systems.
When using an external 2-Wire hard wired connecon, only channels that are
connected to a wired intercom will be able to share audio between BaseStaons.