User manual
Clear-Com Intercom Systems KB-211/KB-211GM Two-Channel Speaker Stations
© Clear-Com Intercom Systems 1999
15
Rev. A
• The call signal does not function.
Scenario 1
Excessive DC loading of intercom line.
Solution: Remove any audio transformers or other equipment that may be
connected across the intercom line. If equipment other than Clear-Com
intercom equipment must be connected to the intercom line, please contact
Clear-Com application or service personnel for information or
recommendations.
Scenario 2
Far too many terminations on the intercom line.
Solution: Check all main stations and power supplies to make sure each
intercom channel is terminated at only one point.
Scenario 3
Plug P1 is missing on circuit board.
Solution: Plug P1 must be installed in the J1 jack if the EB-4W or EB-TW
options are not used.