Installation manual
The Program Level control can be used to adjust the stage microphone audio level the Stage Manager
hears. If or whenever the Stage Manager does not need to monitor this, the Program Level control can
be turned fully counter-clockwise.
Channel B is connected to Speaker Stations such as the Clear-Com KB-112 which are installed in the
green room and in dressing rooms. These Speaker stations should be optioned for Normal operation,
which enables the speaker and allows a push-to-talk function for replying to the Stage Manager. Chan-
nel B on the Main Station would typically be programmed as follows:
The Momentary Talk B option switch must be set to the ON position. This will cause the Channel B
Talk button to have a momentary only action and not latch. The Stage Manager could then only be
heard by the actors and actresses in the Green Room and Dressing Rooms when the Channel B
Talk button is held down.
The Channel B On-Off-Interrupt switch must be set to the INTERRUPT position. This causes the
Channel B Talk button to interrupt the audio from the stage microphone.
The Channel B Program Level trimpot should be adjusted to a comfortable level in the Speaker
Stations.
The stage microphone audio can then be heard by the actors and actresses in the green room and
dressing rooms. The stage microphone audio heard by the waiting actors and actresses will be inter-
rupted whenever the Stage Manager talks to them.
Because of the two-channel capability, communication between the Stage Manager and stage equip-
ment operators cannot be heard by the actors and actresses, and vice-versa. This eliminates confu-
sion and miscommunication. If desired, the Stage Manager can turn on the Party Line Link (A+B)
switch on the Main Station during rehearsals to combine the communication between everyone on both
channels.
Clear-Com System Installation Manual
13