User Manual

4.4.7 Checking MVX-A16 analog port card installation
The following front panel lights indicate that an analog port card has been properly installed
in the matrix:
Figure 7: MVX-A16 card lights
Tip: For more detailed information about the MVX-A16 front panel controls and lights, see
5.6 MVX-A16 analog card front-panel lights and controls.
RESET
+3.3V
ACTIVE VOX
+
5
V
-12V
+
12V
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
FRAME
DATA
STATUS
One of the four power
-
supply lights
Is lit to indicate that the associated
power supply is operating properly
.
The ACTIVE lights
correspond to the card’s
16
ports.
When lit, an
active
light indicates that
RS
422 data is being
received.
The
VOX
lights
corresponds to
the card’s
16 ports. When lit, a
VOX
light indicates the audio
level on that port’s connected
audio device has exceeded a
threshold
.
The threshold audio
level is set for that port’s
connected audio device in EHX
.
The frame data
light
flashes
steadily (
1:
1 0.5 Hz)
when
information has successfully
passed between the CPU
card and the
MVX
-A
16 card.
The
status
light i
s lit red when the
MVX
-A
16
card fails to communicate
with the CPU card
.
38
Eclipse HX-Delta User Guide