User Manual
Table Of Contents
- 1 Important Safety Instructions
- 2 Introduction
- 3 Installation Overview
- 4 Locating System Components
- 5 Powering System Components
- 6 Wiring System Components
- 6.1 Using RJ-45 connectors
- 6.2 Connecting the matrix frame to a PC running EHX
- 6.3 Connecting the matrix frame to an Ethernet network
- 6.4 Connecting the matrix frame to a PC running Production Maestro Pro
- 6.5 Connecting the matrix frame to user panels
- 6.6 General Purpose Outputs (GPOs)
- 6.7 General Purpose Inputs (GPIs)
- 6.8 E & M signalling with an E-QUE E1 / T1 interface card
- 6.9 Connecting the matrix frame to an external alarm
- 6.10 Connecting to a four-wire audio device
- 6.11 Connecting to interface modules
- 6.11.1 Wiring schemes for the FOR-22 interface module
- 6.11.2 Wiring schemes for the CCI-22 interface module
- 6.11.3 Wiring for Clear-Com analog partyline systems (including Encore)
- 6.11.4 Wiring schemes for TEL-14 interface modules
- 6.11.5 Wiring scheme for the RLY-6 interface module
- 6.11.6 Wiring schemes for a GPI-6 Interface module
- 7 Connecting Matrix Frames
- 8 Glossary

6.11.5 Wiring scheme for the RLY-6 interface module
The RLY-6 interface module provides six fully programmable SPDT (single pole, double
throw) relay outputs, to support dedicated switching functions external to the matrix frame .
RLY-6 interfaces can be:
• Daisy chained to provide connection of up to 60 relays to the matrix.
• Mixed with GPI-6 modules up to the total limit of 60 items. Five RLY-6 and five
GPI-6 modules would provide 30 relays and 30 inputs for a total of 60 inputs and
outputs.
Note:
If both GPI-6 and RLY-6 interface modules are used the GPI-6 interface module must be
placed first in the daisy chain.
Tip: For more information about wiring the RLY-6, see the RLY-6 manual.
Wiring the RLY-6 to an IMF-3 interface frame
To connect the RLY-6 to the IMF-3 frame:
1. Connect one end of an RJ-45 cable (eight wires with no reversal) into the GPI/RLY
INTERFACE connector on the back of the matrix.
2. Connect the other end into the top RJ-45 (CH. A MATRIX) connector for the RLY-6.
To connect an additional RLY-6 interface to the IMF-3 frame:
1. Connect one end of a short RJ-45 cable into the lower RJ-45 (CH. B MATRIX) for the
first RLY-6.
2. Connect the other end of the cable into the top RJ-45 (CH. A MATRIX) connector for
the additional RLY-6.
Additional RLY-6 Interfaces are added in the same way, using daisy-chain wiring. If there are
multiple RLY-6 modules, the relays in the first module will be numbered 1 to 6, the relays in
the second module will be numbered 7 to 12, and so on. GPI-6 modules can be mixed in this
daisy-chained scheme. The maximum combined length of all the RJ-45 cables should not
exceed 20 feet (6 m).
64