User Manual
Table Of Contents
- 1 Important Safety Instructions
- 2 Introduction
- 3 Installation Overview
- 4 Locating System Components
- 5 Powering System Components
- 6 Wiring System Components
- 6.1 Using RJ-45 connectors
- 6.2 Connecting the matrix frame to a PC running EHX
- 6.3 Connecting the matrix frame to an Ethernet network
- 6.4 Connecting the matrix frame to a PC running Production Maestro Pro
- 6.5 Connecting the matrix frame to user panels
- 6.6 General Purpose Outputs (GPOs)
- 6.7 General Purpose Inputs (GPIs)
- 6.8 E & M signalling with an E-QUE E1 / T1 interface card
- 6.9 Connecting the matrix frame to an external alarm
- 6.10 Connecting to a four-wire audio device
- 6.11 Connecting to interface modules
- 6.11.1 Wiring schemes for the FOR-22 interface module
- 6.11.2 Wiring schemes for the CCI-22 interface module
- 6.11.3 Wiring for Clear-Com analog partyline systems (including Encore)
- 6.11.4 Wiring schemes for TEL-14 interface modules
- 6.11.5 Wiring scheme for the RLY-6 interface module
- 6.11.6 Wiring schemes for a GPI-6 Interface module
- 7 Connecting Matrix Frames
- 8 Glossary

DB-25M Connector
Pin
Description
Relay
Pin 1
Common
RELAY1
Pin 2
Normally closed
Pin 3
Normally open
Pin 4
Common
RELAY2
Pin 5
Normally closed
Pin 6
Normally open
Pin 7
Common
RELAY3
Pin 8
Normally closed
Pin 9
Normally open
Pin 10
Common
RELAY4
Pin 11
Normally closed
Pin 12
Normally open
Pin 13
Digital ground
-
Pin 14
Common
RELAY5
Pin 15
Normally closed
Pin 16
Normally open
Pin 17
Common
RELAY6
Pin 18
Normally closed
Pin 19
Normally open
Pin 20
Common
RELAY7
Pin 21
Normally closed
Pin 22
Normally open
Pin 23
Common
RELAY8
Pin 24
Normally closed
Pin 25
Normally open
Table 12: Pin configuration of the GPO connector (DB-25M)
Note:
See also Figure 10: Pin configuration of the GPO connector (DB-25M) below.
42