User Manual
Table Of Contents
- 1 Important Safety Instructions
- 2 Introduction
- 3 Installation Overview
- 4 Locating System Components
- 5 Powering System Components
- 6 Wiring System Components
- 6.1 Using RJ-45 connectors
- 6.2 Connecting the matrix frame to a PC running EHX
- 6.3 Connecting the matrix frame to an Ethernet network
- 6.4 Connecting the matrix frame to a PC running Production Maestro Pro
- 6.5 Connecting the matrix frame to user panels
- 6.6 General Purpose Outputs (GPOs)
- 6.7 General Purpose Inputs (GPIs)
- 6.8 E & M signalling with an E-QUE E1 / T1 interface card
- 6.9 Connecting the matrix frame to an external alarm
- 6.10 Connecting to a four-wire audio device
- 6.11 Connecting to interface modules
- 6.11.1 Wiring schemes for the FOR-22 interface module
- 6.11.2 Wiring schemes for the CCI-22 interface module
- 6.11.3 Wiring for Clear-Com analog partyline systems (including Encore)
- 6.11.4 Wiring schemes for TEL-14 interface modules
- 6.11.5 Wiring scheme for the RLY-6 interface module
- 6.11.6 Wiring schemes for a GPI-6 Interface module
- 7 Connecting Matrix Frames
- 8 Glossary

5.3.2 IMF-102
The IMF-102 has an internal power supply and a rear panel connector for connecting
redundant power. The power supply is universal, operating over a voltage range of 90 - 250
VAC. The maximum dissipation is 20W.
Tip: An additional power supply can be added for redundancy by connecting a PSU-101
power supply to the power connector on the rear panel.
For more information, see the IMF-102 Interface Module Instruction Manual.
5.3.3 Current capacities and consumption
The current capacities of the power supplies are as follows:
+9 V analog 3.0 A
-9 V analog 3.0 A
The following chart provides the current drain of the +/- analog power supplies for interface
modules and the IMF-3 interface frame.
Note:
Some devices, such as interface modules, have a varying current depending on the
operation of features. In Eclipse HX devices where it is possible to activate all operating
features of all components used, use the maximum current column for planning.
Component Average current Maximum
IMF-3
0.20 A
0.20 A
CCI-22
0.00 A
0.00 A
FOR-22
0.07 A
0.15 A
TEL-14
0.28 A
0.37 A
RLY-6
0.10 A
0.15 A
GPI-6
0.02 A
0.02 A
AES-6
0.16 A
0.16 A
Table 6: Interface current consumption
30