Instruction Manual
Table Of Contents
- The Eclipse Omega Matrix System: An Overview
- Operation
- The Eclipse Omega Matrix and Circuit Cards
- Front-Panel Controls and Lights
- Central Processor Unit (CPU) Card Description
- Analog Port Card Description
- Power Supply Description
- Connecting the Matrix
- Eclipse Fiber Linking
- Eclipse E-QUE Interface
- Eclipse IVC-32 Interface
- Eclipse LMC-64 Interface
- Installation
- Reconnecting the CPU Card’s Backup Battery
- Verifying the Shipment
- Unpacking the System
- Installing the Eclipse Omega Matrix
- Installing Power Supplies
- Installing the Rear RJ-45 Connector Panels
- Installing Rear RJ-45 Connector Panels in the Field
- Installing CPU Cards
- Installing Analog Port and Expansion Cards
- Wiring Audio Devices to the Matrix
- Wiring CPU Card Interfaces
- GPI/RLY Interface Connector
- RS-232 DB-9 Connector
- Alarm I/O Connector
- General-Purpose Outputs Connector (GP OUT)
- General-Purpose Inputs Connector (GP IN)
- Local Area Network Connectors (LAN1 and LAN2)
- E1/T1 Matrix to Matrix Crossover Cable
- E1/T1 Straight Cable Connections
- E1 to FreeSpeak/CellCom Antenna Pinout
- Maintenance
- Specifications
- Glossary
- Limited Warranty
- Technical Support & Repair Policy

Clear-Com
Eclipse Omega Instruction Manual
1-7
network, allowing the system administrator to control the matrix
remotely.
INTERCOM PANELS AND ACCESSORY PANELS
All intercom panels connect to the central matrix via shielded
category-5 cable terminated with RJ-45 connectors. The shielded
category-5 cable connects to the matrix through the MVX-A16 analog
interface. The following Clear-Com intercom panels are compatible
with the Eclipse Omega matrix system:
• V12LD, V24LD, V12PD, V24PD, V12RD, V24RD, V12LDD,
V12PDD, V12RDD, V12LDE, V12PDE and V12RDE V-Series
panels
• 4215E, 4224E, 4226E, 4294E, 4212E, 4222E, 4203E, 4206E,
4230E and 4230VE 4000 Series II panels
• i-Station family, including expansion panels
• ICS-2003 intercom panels, including expansion panels
• ICS-52 and ICS-92 intercom panels, including expansion panels
• ICS-62 and ICS-102 intercom panels, including expansion panels
• ICS-1008 and ICS-1016 intercom panels, including expansion
panels
• ICS-21, ICS-22 and ICS-24 panels have limited support
Each of these panels is described in its own manual. For a full
description of the operation, installation, and maintenance of a panel,
refer to the appropriate panel instruction manual.
INTERFACE MODULES
Interface modules convert the 4-wire signals of a central matrix port to
other types of signals that communicate with devices such as
telephones, camera intercoms, two-way radios, and so on. In this way
non-4-wire devices can communicate with the central matrix.
Each interface module has hardware connectors to connect to both the
central matrix and to the external device that communicates with the
central matrix. Most interface modules connect to the central matrix via
shielded category-5 cable terminated with RJ-45 connectors. The
DIG-2 digital interface module, however, connects to the central matrix
via double-shielded 24 AWG conductor category-6 enhanced
(CAT-6E) STP cable.
The type of cable used to connect the interface module to the
non-4-wire device varies with the device. Each of these connections is
described more fully in the individual manual for each interface.
The following interface modules are compatible with the Eclipse
Omega matrix: