Instruction manual

ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL
7-3
Backplane Connector: FCI/BERG Metral
Port Connector RJ-45 to Clear-Com standard pinout
Transmission Distance 3000 ft. (1000 m) maximum
System Programming
Group Calls 100
Number of Grouped Ports 4000 maximum
Conferences per Matrix 64
IFB per Matrix 100
Priority Levels 5
Isolates Any crosspoint
Listen Level Control 0.71 dB steps
Input Level Control 0.355 dB steps
Output Level Control 0.355 dB steps
VOX Input Detection Threshold 0 dB to – 32 dB adjustable
Minimum PC Requirements
Processor Pentium III 600 MHz (minimum
recommended)
Memory 512 MB RAM minimum
Hard Disk 500 MB free space
Input Devices 3.5-inch Floppy Disk Drive, CD-ROM Drive
Display Resolution SVGA
User Entry Keyboard, Mouse
Ports 2 serial ports
Network IEEE 802.3 Ethernet Card
Operating Systems Windows XP Professional SP2 / Server 2003
SP1 / 2000 SP4
Note: For details of software requirements please refer to the ECS User Manual part no.
810299.
Power Supply Unit
Format Euro Cassette
Quantity 2 per matrix
Mounting Front
Backplane Connectors Positronics
AC Power Input IEC (1 per PSU)
Input Voltage AC 100 V to 240 V, 50/60 Hz
Power Consumption 400 W maximum
Status Indicators LEDs viewable from front of rack
Notice About Specifications
While Clear-Com makes every attempt to maintain the accuracy of the
information contained in its product manuals, that information is subject to
change without notice. Performance specifications included in this manual are
design-center specifications and are included for customer guidance and to
facilitate system installation. Actual operating performance may vary.