Instruction manual
ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL
4-6
Where multiple connected matrices are used containing E-Que cards the DECT
reference ports are connected as a daisy chain between the matrices to ensure that
the DECT signals are synchronised through all the E-Que cards present in the
matrices.
The LAN port is used for diagnostic purposes.
E-QUE CARD APPLICATIONS
The E-Que card may be used to connect FreeSpeak/CellCom antennas and
splitters to an Eclipse matrix system.
FREESPEAK/CELLCOM APPLICATION
The E-Que cards can be configured for FreeSpeak/CellCom use in two modes
depending on whether antennas or splitters are to be connected.
If the E-Que card is configured in ‘Antenna’ mode all eight E1/T1 ports can be
used to connect up to eight antennas. If the E-Que card is configured to support
splitters only two ports are active (ports 1 and 5) allowing a maximum of two
splitters to be connected. Each splitter can support up to five antennas.
There connections schemes are illustrated below.