Instruction manual

ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL
2-6
When a non-active configurations number appears in the display, it flashes to
indicate its non-active status. When an active configurations number (either 1,2,
3, or 4) appears in the display, it illuminates solidly (without flashing) to indicate
that it is the active configuration.
To select one of the four configurations from the CPU card:
1. Repeatedly press the CONFIG button until the desired configurations
number (1,2,3, or 4) appears in the display.
2. When the desired number appears, press and hold the CONFIG button until
the display stops flashing. This should take about three seconds.
The selected configuration then becomes the systems active operational
configuration.
Engineering “ENG” Button
This button is used to reset the system to the default IP addresses.
Full Reset Button
When you perform a full reset, all cards in the matrix reset regardless of any
system preferences in the program software and non-volatile memory is cleared.
To perform a full reset:
1. Press and hold the cards lower RESET button (the “full reset” button).
2. Simultaneously press and release the card’s upper RESET button.
3. Continue holding the cards lower RESET button for two seconds.
The card performs a full reset.
The same configuration that was active before you reset the system will be active
after you reset it.
When the cards and connected audio devices reset, they momentarily stop their
current activity and restart. During this process configuration information is
downloaded to the cards and audio devices from the CPU card’s non-volatile
RAM.
Note: Under normal operating conditions it is not necessary to perform a full
reset. Technical personnel might perform a full reset if they believe that the
CPU card is operating incorrectly as a result of corruption of the
microprocessors internal data or instruction sequence.
6
7