Instruction Manual
17 Tempest®24 00 MasterBelt
The MasterBelt default is for Dynamic Slot Assignment. This means that when BeltSta ons log in to a MasterBelt, the
informa on about the BeltSta ons is displayed on the MasterBelt LCD screen in alpha-numeric order according to the
name of the BeltSta on. For example, “Dir” appears before “Light1,” which appears before “StgMgr,” but they can change
slots depending on which BeltSta ons are turned ON. If the default se ngs are used, nothing is necessary.
Adjus ng so that each BeltSta on always appears in the same posi on of the MasterBelt display is a two step process:
1. Advance to the MasterBelt’s “Slot Assignment” sec on of the “Tech Menu” and select
Sta c.
2. In each BeltSta on, advance to the “Base Slot” sec on of the “Tech Menu” and adjust each BeltSta on to a diff erent
slot (1 – 5). The BeltSta on designated to slot 1 will always appear on the far le of the MasterBelt display, with slot 2
appearing in the next posi on to the right, and so on.
In
Sta c Mode, if a BeltSta on is not turned ON, or is logged out due to being out of range, the MasterBelt LCD display
will not have a shadow box around the respec ve slot number.
A Mul ple MasterBelt system that uses iSelect Roaming must choose to use “Dynamic” slots to ensure that BeltSta ons can
move from MasterBelt to MasterBelt when roaming.
Addi onal Se ngs and Features
Below are addi onal MasterBelt and BeltSta on se ngs that can be set based on individual preferences. None of these
adjustments are required and some features are limited to either the MasterBelt or BeltSta on:
•
Select Base - BeltSta ons can be paired with up to 64 MasterBelts (or BaseSta ons); Press MENU, select “Select
Base” and choose the to enable that BeltSta on to access a respec ve MasterBelt or BaseSta on.
•
Lock Keys - to prevent inadvertent changes. Press MENU, select “Lock Keys” to access lock op ons. Default se ng
is unlocked.
•
Menu Lock - allows you to lock individual users out of their respec ve BeltSta on menu en rely. Access can only be
regained by entering a 3-digit security key code (which is ini ally set at the MasterBelt) on each BeltSta on. Default
key code se ng is 000 and menu lock is disabled.
» To set key code at MasterBelt: Press MENU, select Belt Se ngs>Tech Menu>Belt Key; use volume knob to
scroll and set a key code. Press ENT to save.
» To enable “Menu Lock” at BeltSta on - Press MENU, select Lock Keys>Menu Lock
•
Ba ery Alert - Enable or disable the audible “Ba ery Alert” tone in the headset; Press MENU, select “Ba ery” and
Enable or Disable. Default se ng is Enable.
•
LCD/LED - Dim the LCD and LEDs to be less conspicuous in a dark environment:
» To enable or disable “LCD Light”: Press MENU, select LCD/LED>LCD Light
» To adjust the LED brightness: Press MENU, select LCD/LED>Talk LEDs and select either
High/Med/Low/Off .
•
Talk Bu ons - Set the TALK bu ons to operate in Latch or Momentary mode or Disable them completely. Press MENU,
select Set Controls>Talk Bu ons>Talk # and select either Latch/Momentary/Disable. Default se ng is Latch.
•
Channel (CH) Select - determine which channels are accessible and audible per MasterBelt or BeltSta on. Unit must
be set to access at least one channel. Press MENU, select Set Controls>Ch Select and choose from the channel
con gura ons available. Default se ng is access to all channels.
•
Mic Gain - Refer to the sec on “Adjust Mic Gain” in this manual.
•
Sidetone - Refer to the sec on “Adjust Sidetone” in this manual.