CLEANMAX OPERATING INSTRUCTIONS FOR C LEAN M AX NITRO UPRIGHT VACUUM MODEL : CMNR-QD Before operating the vacuum, please read these instructions completely.
Index Important Safety Instructions 2 Grounding Instructions 3 Parts Identification 4 Replacement Bags, Belts and Filters 4 How to Assemble and Operate the Vacuum 5 How to Adjust the Handle 5 How to Attach the Extension Power Cord 6 Nozzle Height Feature 6 Edge Cleaning Feature 6 How to Change the Vacuum Bag 6 How to Change the Filters 7 Cleaning with On-Board Tools 7 How to Replace the Vacuum Belt 8 Thermal Motor Protection 9 Troubleshooting 10 Fo
IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. WARNING! To reduce the risk of fire, electric shock, or injury: 1. D o not leave appliance unattended when plugged in. Unplug from outlet when not in use and before servicing. 2. WARNING: ELECTRIC SHOCK COULD OCCUR IF USED OUTDOORS OR ON WET SURFACES. 3. D o not allow to be used as a toy. Keep children and unauthorized persons away from the machine when in use. 4. Use only as described in this manual.
Grounding Instructions This appliance must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
Parts Identification Handle grip Stretch hose Hose handle Handle tube Cord storage hooks Hose handle release button Telescopic wand Metal cord hook Power cord Bag compartment cover latch Bag compartment Pigtail cord Crevice tool Easy-carry handle Dusting brush Quick clean-out port Furniture guard Handle release pedal Nozzle Replacement Bags, Belts and Filters • Genuine CleanMax Paper Bags Part # CMP-12, 12 per package •G enuine CleanMax Belts Part # CMNR-B2, 2 per package • Genuine Clea
How to Assemble and Operate the Vacuum How to Attach the Handle to the Vacuum Cleaner The vacuum and the handle are packed separately. 1. After first removing the handle screw, slide the handle into the slot on top of the vacuum cleaner. 2. Line up the small hole on the handle with the small hole on the vacuum cleaner and insert the screw. Make sure the screw is tightened securely (Fig. 1). On/Off Pedal 1.
How to Attach the Extension Power Cord How to Attach the Extension Power Cord to the Cord Lock 1. Connect the extension power cord to the pigtail cord on the vacuum. 2. Snap the extension power cord into the slot on the end of the cord lock. 3. Turn the knob on the bottom of the cord lock to tighten the lock and prevent the cords from pulling apart (Fig. 1). How to Attach the Cord to the Retainer Hook on the Handle 1.
How to Change the Filters Your vacuum cleaner is equipped with a secondary filter and a HEPA media filter. These filters capture fine dust particles and protect the motor from dirt. Accumulated dirt in the bag compartment will be collected on the filters and may restrict motor performance. It is important to change the filters regularly — approximately once a year or as needed. How to Change the Secondary Filter 1. Unplug the vacuum cleaner. Remove the bag compartment cover and remove the vacuum bag. 2.
cleaner face down, in a flat position on a soft Removing brush bar and belt surface (eg. carpet). 4. Using a cross-headed screwdriver, unscrew the 5 Removing brush and belt to release the screws on the basebar of the cleaner L-shaped plate from over the rotaryunscrew brush bar. 4. Using a cross-headed screwdriver, the 5 screws on the base of the cleaner to release the L-shaped plate from over the rotary brush bar. 7. ensuring th belt. the rot Pass ensuring the belt.
Thermal Motor Protection Your CleanMax vacuum cleaner is equipped with a thermal protector designed to protect your vacuum cleaner from overheating due to restricted airflow (i.e. clogged hose). Should this situation occur, the thermal protector will automatically shut off the motor to prevent damage. How to Reset the Thermal Protector 1. U nplug the vacuum cleaner. 2. A llow the vacuum cleaner to cool at least 30 minutes. 3.
Troubleshooting Problem Check Point Possible Solution Suction power is weak. • Vacuum bag • Wand or hose • Filters • If the vacuum bag is 2/3 full, replace it. • If clogged or blocked, remove the object. • Clean or replace filters. The vacuum does not work. • Power cord Insert the power plug firmly into an electrical outlet. Sudden loss of power. • Thermal reset Turn off vacuum and unplug from electrical outlet. Let vacuum cool down for at least 30 minutes before turning back on.
Warranty What Is Covered: This warranty covers any defects in material and workmanship in your new CleanMax vacuum. How Long Coverage Lasts: Warranty coverage for the CleanMax vacuum lasts one year. What Is Not Covered: • Damage to the vacuum that occurs from neglect, abuse, alterations, accident, misuse or improper m aintenance. • Normal replacement items: belts, filters and disposable bags.