Product Manual
7578 Page 7 11-01-12
ECN 3783
PARTS LIST
ITEM
QTY
CM216
CM230
DESCRIPTION
1
1
54105
54098
PUMP ASSEMBLY 115V
2
1
53673
53673
CONTROL BOX ASSEMBLY
3
1
8136
8136
METAL GRATE
4
1
8135
8135
STRAINER
5
1
54268
54268
DOOR CLOSURE ASSEMBLY
6
1
6024
6024
FLEXIBLE HOSE
7
1
8169
8169
BRUSH, FLO THRU
8
1
53665
53665
BRACKET, CTRL BOX
9
1
7317
7317
PUMP, 115V 50/60HZ 205GPH
10
1
8025
8025
PLUG, 15A
11
1
57041
57041
POWER CORD
12
1
8022
8022
RECEPTACLE 115V
13
1
01122
01122
SWITCH, ROCKER
14
OPTION
7197 (16 GAL)
7322 (30 GAL)
DRUM, METAL
V. TROUBLESHOOTING
A. Machine does not operate:
1. Make sure the parts cleaner is connected to electric power or air supply.
2. Check for incoming power. Check serial plate for power requirements.
3. On electric units: check reset button on GFCI cord to make sure it is not tripped.
On air units: an increase in air supply may be required.
B. Little or no fluid flow through the flow-thru brush:
1. Turn pump switch “ON” or increase air pressure.
2. Check the fluid level in the tank.
3. Check pump intake for obstructions.