Product Manual

7578 Page 7 11-01-12
ECN 3783
PARTS LIST
ITEM
QTY
CM216
CM230
1
1
54105
54098
2
1
53673
53673
3
1
8136
8136
4
1
8135
8135
5
1
54268
54268
6
1
6024
6024
7
1
8169
8169
8
1
53665
53665
9
1
7317
7317
10
1
8025
8025
11
1
57041
57041
12
1
8022
8022
13
1
01122
01122
14
OPTION
7197 (16 GAL)
7322 (30 GAL)
V. TROUBLESHOOTING
A. Machine does not operate:
1. Make sure the parts cleaner is connected to electric power or air supply.
2. Check for incoming power. Check serial plate for power requirements.
3. On electric units: check reset button on GFCI cord to make sure it is not tripped.
On air units: an increase in air supply may be required.
B. Little or no fluid flow through the flow-thru brush:
1. Turn pump switch “ON” or increase air pressure.
2. Check the fluid level in the tank.
3. Check pump intake for obstructions.