Product Manual
7578 Page 5 11-01-12
ECN 3783
4. INGESTION (Swallowing): Uncontaminated cleaning solvent: Drink 4 to 8 ounces of water
and seek medical attention. DO NOT induce vomiting.
E. Environmental
1. Avoid spilling solvent. Spilled solvent can create slippery conditions, clean it up immediately.
Close off area to traffic. Wear appropriate personal protective equipment to prevent eye and skin
contact. Consult the Material Safety Data Sheet for instructions on clean up and disposal.
2. Contain leaks promptly. Notify local environmental authorities if necessary.
3. Solvents, when used to clean grease and oil, must be disposed of properly. Consult your
local environmental management agency for additional guidance and other potentially
hazardous materials compliance requirements.
4. Do NOT remove devices designed to reduce solvent evaporation except to process work or
to perform maintenance.
5. For further information consult the Material Safety Data Sheet provided by the solvent
supplier.
III. Installation
A. Position the drum on a hard level surface in a well-ventilated area.
B. Remove the parts packed inside the unit and inspect for damage.
C. Place the sink on its side.
D. Hook the pump assembly to the bracket on the bottom side of the sink.
E. Feed the pump cord through the large hole in the pump plate on the back of the machine,
and snap the cord cover in the hole.
F. Feed the hose from the pump through hole in the pump plate on the back of the machine,
and attach to the hose-barb on the back of the sink. Secure with a hose clamp.
G. Place the sink onto the drum.
H. Place the strainer and grate in the drain hole in the bottom of the sink.
I. Place the control box in the bracket on the right side of the machine.
(Star washer must be installed between screw head and painted surfaces to insure proper
ground continuity.)
J. Using the screw and star-washers, fasten the control box to the control box bracket.
K. Plug the pump cord and light cord (if equipped) into the receptacle on control box.
L. Plug the power cord into a properly grounded power source. Check serial plate for power
requirements.
Power Requirements = 15 amp, 115 volt, 60 Hz
M. Fill solvent reservoir with mineral spirits based solvents with a flash point greater than 40ºC
(104ºF)
Capacity Model E216 = 37.9 L. (10 gal.).
Capacity Model E230 = 75.7 L. (20 gal.).