CL�NFORCE better air, better life , I f f f f .... BBB: ....
II Contents • Important Safety Instructions - - - - - - - - - - - - - - - - - - - - 2 • Technical Specifications - - - - - - - - - - - - - - - - - - - - - - - - 6 • Operating Instruction - - - - - - - - - - - - - - - - - - - - - - - - - - 7 • Changing the filter - - - - - - - - - - - - - - - - - - - - - - - - - - - 12 • Care and Maintenance - - - - - - - - - - - - - - - - - - - - - - - -15 • Warranty Policy - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17 • Warranty Card - - - - - - - - - - -
II Important Safety Instructions & Read all instructions before using this air purifier to reduce any risk of fire, electric shock, or injury. To ensure safety, store these instructions for future use and make them accessible to other users. Make sure to include these instructions when handing over the air purifier to third parties. • This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way.
• Do not place the air purifier near wet areas, including bathrooms and laun dries. • To ensure safety with the power cord. Powr cord should not run under rugs, runners or carpets as it can be a trip hazard. Don't pull, carry or trap the power cord under doors or sharp edges. Do not unplug the air purifier by pulling on the power cord. • Don't handle the plug or air purifier with wet hands. • Don't use the air purifier with incorrect voltage as this may result in damage or injury to the user.
II Blueprint O fJ LED Display 8 Touch Button C, Air Outlet 0 0 8 0 Plastic Net Pre-filter Multi-Integrated Filter (Non-woven cloth, HEPA filter, Activated carbon filter) C, (!) Left Cover 4 Wheels Brushless direct current motor with Twin-Turbo Fan Plastic Net Pre-filter Right Cover Accessories USER MANUAL Multi-Integrated Filter x 2 Pre-filter x 2 Remote control 4
II LED Display Instructions • • Filter ---1 A ,- , , -, fT'"I •©--- • :b 5 l_J (_J l_J PM2.5 µg/m' O LED Display 0 8 0 CD Child Lock Mode On A Automatic Mode On Air Inlet 8 Filter Service Life 8 O PM2.
II Specifications Purification Area: Clean Air Delivery: 85m2 (915 sq.ft) Smoke Dust Pollen >560 >560 >560 ft /min >950 >950 >950 m3 /h Rate(CADR) 3 Power: 88W Noise Level: 35-64dB Motor Type: DC Motor Voltage: 120V 60Hz Air Exchange: 5 per hour ( 85m2 or 915 sq.ft.room) Average fitler service life: Dimensions: 6 months Width: 370mm ( 14.57 inches) Depth: 400mm (15.55 inches) Height: 796mm (31.5 inches) Weight: 16.5KG (36.
II Operating lnstrctions Read all instructions before using your CleanForce air purifier. Unpack and remove all packing material. Remove your CleanForce air purifier from the plastic bag. Completely unravel the power cord and place your CleanForce air purifier on a flat, dry, stable surface. Be sure to place your CleanForce air purifier at least 12 inches(30cm) away from the wall on ALL sides. The air output vent should face towards the room - failure to do so may reduce unit efficiency.
O Open the covers on both 8 Take out the sides of the air purifier Multi-Integrated Filter 8 Remove all the plastic O C, Install the both side (3 Plug in the air purifier outer packages covers back Install the Multi-Integrated Filter Press the power key 8
Plug in your CleanForce air purifier and press the power key to turn the unit on. Next the machine will start the automatic mode, and the LED lights on both sides of the touch screen panel will display the air quality in four colors. You also can use the remote control to operate your air purifier.
• Filter Reset Key The indicator light for the Filter Reset key will flash in 48 hours, FILTER before the end of the filter service life, to remind the customer to replace the filter. Once the filter has been replaced, long-press the Filter Reset key until the flashing light goes out. G2\ w LIGHT • Light Key When the air purifier is turned on, the LED lights (on both sides of the touch screen panel), will automatically turn on and display the air quality in four colors.
• Speed Key SPEED The CleanForce air purifier features four different speed settings: very high/high/medium/low. The LED display indicates different speed settings. Filter ----- ;ouo PM'·' ,UUU.,.,m· Filter ----- ;uI_U.,.,m· o "" ' ,UH iJl, iJl, iJl, iJl, iJl, iJl, iJl, Very high High Fitter ----- ;ur10 ""·' ,UUU.,.
II Changing the fiter General Information Clean Force MEGA 1 OOO air purifier consists of two plastic pre-filters and two Multi-Integrated Filters. ---- · -- Plastic Pre-filter MultiIntegrated Filter The plastic pre-filter removes @ Hair ® Pet Dander @ Pollen � Lint •• • •••• PM10 PM10 The Multi-Integrated Filter is composed of non-woven cloth, HEPA filter, and activated carbon filter. It removes: 0. Dust (2) \ Smoke @) ® ® Dust Mites Bacteria Virus @ ® Chemicals Cooking Odors VOCs
II Replacement Steps When the indicator light of the Filter Reset key flashes, the filters will need to be changed. O Turn off the air purifier and unplug it.
Q 0 Remove all the plastic outer 0 Multi-Integrated Filters packages of the new filter Install the both side covers back Install the new 8 Plug in the air purifier, Press the filter key more than 3 seconds Note: 1. You should not miss this reset step or the air purifier may not operate normally. 2. The plastic pre-filter does not need to be replaced if there is no damage. It only needs to be regularly cleaned and dried then put back into the machine.
II Care and Maintenance In order for your air purifier to operate at optimum capacity, please follow the steps below for regular maintenance • Covers(Air Inlet) Remove the covers on both sides of the machine, clean the cover regularly with water or vacuum cleaner. • Pre-filter Clean the plastic pre-filter regularly with water or vacuum cleaner. • Fan Regularly clean the fan port with a vacuum cleaner. Do not wash with water or dismantle the fan.
II Troubleshooting Problem Unit does not turn on The air outlet does not produce air The unit does not work after replacing the filters. Check • Power socket • Power cord • Covers on both sides of the unit • Plastic outer filter packaging has been removed • Whether air outlet at top of air purifier is blocked Solution • Check whether the power socket is damaged. • Check whether the power cord is damaged. • If the covers do not install correctly, please reinstall them.
II Warranty Policy Dear User, If you encounter problems with your air purifier, or your expectations for your CleanForce product are not met, you can contact us using either of the following methods: Call our service hotline: +1 213 289 3385 Or contact us by email: support@cleanforceair.com Your CleanForce air purifier is guaranteed and warranted against defects in material and workmanship, under normal residential use, for up to 2-years from the date of purchase. (excluding filters).
II Warranty Card Product Name/Model Date of Purchase Where purchased Customer Name Address Phone Number Email Maintenance record 18