Safety Information

Report No. 200501897SHA-001
CleanForce Environmental Protection Technology Co., Ltd.
Issued: 15-Jul-2020
Revised: None
Evaluation Period Project No. 200501897SHA
Sample Rec. Date 7-May-2020 Condition Prototype Sample ID. 0200507-02
Test Location
Test Procedure
UL 507:2017
Ed.10+R:27May2020
Clause
41
44
45
46
47
50
53
54
57
61
62
63
64
65
72
/
/
UL 1004-1:2013
Ed.2+R:07Aug2018;
UL 1004-3:2015
Ed.2+R:31Jan2018
Clause
8
9
37
Completed by:
Reviewed by:
Title: Title:
Signature: Signature:
6.12
6.5
6.4.5
6.6.4
6.14
6.11
Certification Engineer Technical Supervisor
A representative sample of the product covered by this report has been evaluated and found to comply with
the applicable requirements of the standards indicated in Section 1.0.
6.24
6.25
6.26
/
Dielectric Voltage-Withstand Test
Locked Rotor Endurance Test
Locked Rotor Temperature Test
Component Breakdown Test
8.1 Signatures
Frederic Yang Jack Tang
6.29
Test Description
CSA C22.2#100:2014 Ed.7+U1;
CSA C22.2#77:2014 Ed.8+E1
Clause
Abnormal temperature
Impact test (enclosures)
Stability Test
Static Force Test on Guards
Impeller Test for Portable Fans
Impeller Ignition Test
Impact Test on Guards
8.0 Test Summary
Building No. 86, 1198 Qinzhou Road (North), Shanghai 200233, P. R. China
Testing Lab
Test Description
2020-05-15 to 2020-06-23
Determination of the result includes consideration of measurement uncertainty from the test equipment and
methods. The product was tested as indicated below with results in conformance to the relevant test criteria.
The following tests were performed:
CSA C22.2#113:2018 Ed.11
Clause
Leakage Current Test
Starting Current Test
Input Test
Temperature Test
Dielectric Voltage Withstand Test
6.4
6.5
6.8
6.10
6.3
Push Back Relief Test
6.28
Humidity Conditioning Test
Locked Rotor Test
6.11
6.30
Strain Relief Test
6.9
ED 16.3.15 (20-Apr-17) Mandatory