Application Guide

Test Report Number: 200501108SHA-001
Intertek Testing Services Ltd.,
Page 2 of 4
1. Total Lead (Pb) Content
With reference to US EPA method 3050B/3051, acid digestion method was used and total Lead (Pb) contents were
determined by Inductively Coupled Argon Plasma Spectrometry.
Total Subjects
Result (mg/kg)
Client’s
Requirement
(mg/kg)
(1+4) (2+3) (5+9) 6)
Lead (Pb) <10 <10 <10 <10 100
Total Subjects
Result (mg/kg)
Client’s
Requirement
(mg/kg)
(7+8) (10+11) (12+13) (14+15)
Lead (Pb) <10 <10 <10 <10 100
Remark: Detected Limit = 10mg/kg
# = The result of the mixed samples did not exceed the limit, nevertheless it exceeded the limit/N (N is the number of the mixed
samples). With consideration to dilution factor in a mixed testing, there may be one or more samples failed to meet the
requirement.
*****************************************************************************************************************************************************
To be continued