Owner`s manual
RX Express III Page 5
CleanMaster,
a Division of HydraMaster Corpora-
tion
1/10/00
PUMP PRIMING MODE
Connect the auxiliary pump line supplied with the unit to
the male coupler at the rear of the machine. Disconnect
the vacuum hose intake from the left side of the recov-
ery tank and place the end of the auxiliary line up into
the opening. Using your hand to create a seal around
the line, turn on the vacuum and solution pumps until
you see water coming out of the hose.
EMPTY MODE
Connect the auxiliary pump line to the
male coupler at the rear of the machine
and place the other end into a drain.
Turn on the solution switch and allow
the remaining water to be pumped free.
On the star wheel, two one-inch rubber plugs have been inserted into the plastic hub.
This is to increase the airflow of the electric vacuum motor and speed up drying time.
Remove the plugs when cleaning the star to prevent the buildup of debris in the hub.