Owner`s manual

RX Express III Page 11
CleanMaster,
a Division of HydraMaster Corpora-
tion
1/10/00
WEEKLY...
1. Clean the Recovery Tank thoroughly by
removing the tank and rinsing with clear
water.
DAILY...
1. Clean off any accumulated debris on the gearbox shaft or inside the threaded
portion of the hub. An accumulation of debris around the gearbox shaft, if
not removed, may damage the gearbox oil seal resulting in loss of oil in the
gearbox. If the gearbox is operated without oil, severe damage may occur.
(This requires removing the cleaning head. To do this, please refer to the
“REPAIR GUIDE” section.)
2. Check the applicator jets in the head to insure a proper solution flow. If the
flow is restricted, clean the jets. Twist the jet out. Turn it over. Blow out
any obstructions and reinstall the jet.
NOTE: Do not use any sharp objects to clear obstructions from the jets.
This will damage the jets
CAUTION
!